7. INSTALLATION
• Place the chlorinating cell in an upright position with the
electrical connections facing upwards. If this is not pos-
sible, it can
be mounted horizontally, taking care to ensure that the
small auxiliary electrode is on the top.
• Place the chlorinating cell in the highest possible position
in the treatment circuit, but always after the filter.
• It is essential to have a good earth connection and use a
relay switch with a maximum sensitivity of 30mA.
• Do not obstruct the rear part of the electronic control.
The air should pass through freely to prevent overheating.
• Always disconnect the mains installation before perform-
ing any manoeuvre on the equipment.
• Protect the equipment from the sun and from high tem-
peratures.
• If dose and control equipments are installed, these will be
set always after chlorinating cell.
• The chlorinating equipment will never work unless recir-
culating pump is working.
7.1 HYDRAULIC CIRCUIT AND CONNECTIONS
Las entradas y salidas de la célula se han fabricado para
utilizar tubos de 40mm de PVC internamente o de 50 mm
externamente, utilizando los accesorios necesarios para su
instalación. Se pueden utilizar otras medidas de tubo siem-
pre que se usen los accesorios adecuados.
GB
U S E R G U I D E
1.
From the pool
2.
To the pool
3.
Electrolysis cell
4.
Cell cable
5.
ESAL Base Equipment
6.
Power supply
7
. Filter
8.
Pump cable
9.
Pump
11.
pH sensor. Keep it as far away from
the cell as possible. (approx. 0.5m)
12.
Acid. Keep the acid as far away as
possible from the equipment. If
possible, place the acid in another
room to prevent corrosive gases from
forming.
13.
Acid injector
14.
ESPA EQUAL PLUS pH adjusting
equipment
15.
Four filtering controls and pump
controller