LED6 and buzzer alarm:
Flashes, indicating there is an overload.
-“OVERLOAD”:
Causes:
Corrective action:
The cell sensor is dirty.
Remove the cell and clean it, as explained in the guide.
The cell is not properly connected.
Check that the cell cables are properly connected.
There is a metal object between the cell sheets.
Turn off the equipment and remove the metal object
from the sheets.
The equipment is damaged.
Contact ESPA technical assistance service.
Indication of absence of power in the cell:
The green
LEDs column flashes.
Causes:
Corrective action:
Absence of water flow.
Restore the water flow.
Overload.
Check there is no overload.
Disconnection of the electrolytic cell.
Connect the electrolytic cell.
The chlorinator has stopped during the voltage
The equipment is cleaning the cell by polarity inversion.
inverter process.
This process takes about 5 minutes.