Fault Indicator Lights
Coolant Flow – Will show low coolant flow. The light will briefly show a fault when console is turned
•
on and then go out.
Plasma Gas Pressure -- fault indicator – low plasma gas pressure. Torch will not fire when indicated.
•
Interlock Fault – Indicates Remote Plumbing box door is not properly closed.
•
P/S Temp – fault indicator – over temperature condition in the inverter power source.
•
P/S Fault – Not used.
•
Over/Under Voltage – fault indicator – input voltage is above or below the tolerances of the power
•
source console. Will stay shut down console until main power switch is recycled.
seCtIon 6
trouBleshootIng
6.3 Front panel Fault lights