63
seCtIon 5
MaIntenanCe
Cleaning procedure:
1. Shut console OFF.
2. Remove right side panel (as viewed from the front).
3. Check coolant pressure gauge for a reading of zero.
note:
There is a cooling system line blockage if the gauge does not return to zero when console is turned off. Correct
this problem before continuing.
4. Remove piston plug.
5. Carefully remove spring. Do not distort. Replace with original replacement part if damaged during handling. Failure to
replace with correct spring will change calibration of switch and may damage torch or other components.
6. Remove piston.
7. Clean all parts with mild soap solution and rinse thoroughly with clean water.
8. Reassemble in reverse order.
note:
Use only ESAB replacement parts.
Piston Plug
Spring
Piston
Flow Switch Body
Содержание ESP-200
Страница 1: ...ESP 200 Plasmarc Cutting System Instruction Manual F15 462 C 02 2008 ...
Страница 12: ...12 section 2 description ...
Страница 31: ...31 section 3 installation Plumbing box fully connected including setup pendant ...
Страница 32: ...32 CE 1 2 3 4 5 6 7 9 10 11 12 13 16 19 20 21 22 15 17 18 14 section 3 installation 8 ...
Страница 78: ...78 section 7 replacement parts 7 3 ESP 200 P N 36324 Outside View Front 1 2 3 4 5 6 7 8 9 10 11 12 ...
Страница 80: ...80 section 7 replacement parts 7 4 Outside View Back CE 1 2 3 4 5 6 7 8 9 10 11 CE Unit Only 12 13 ...
Страница 84: ...84 section 7 replacement parts 1 2 3 4 5 6 7 8 9 10 11 12 13 7 6 Right Inside View ...
Страница 88: ...88 section 7 replacement parts 6 1 4 5 6 R ef R ef 2 3 7 8 Back and Top Inside View ...
Страница 92: ...92 section 7 replacement parts 1 2 3 4 5 6 7 8 7 10 Remote Setup Pendant P N 37145 ...
Страница 100: ...100 notes ...