ARES electro-mechanical operator
33
INSTALLATION
6
ELECTRICAL CONNECTIONS
The ARES operators, along with the recommended
switchboards, allow the implementation of a
slowdown system, with the speed slowing down at
the end of the closing and opening operations.
ST1
FT1
P1 P2 P3
ST2
FT2
P4 P5 P6
STOP
P7 P8
P11 P12
LOCK
FCA1
FCC1
P15 P14 P16
P22 P23
Courtesy
Light
Lamp.
G7 G8
G9 G10
24Vac
G4
G5
G6
G1
G2
G3
FCA2 COM FCC2
SCA
P169V
VIVO-M201: 230Vac/50Hz
VIVO-M201M: 125Vac/60Hz
N
L
POWER
MOTOR2 (G2-G1-COM)
MOTOR1 (G2-G1-COM)
G4 G5 G6
G1 G2 G3
A1, A2
Operators
C1, C2
Capacitors
DL4
Gate opening
DL5:
Gate closing
PUL1
Close
mini-pushbutton
PUL2
Open
mini-pushbutton
T
Earth connection
A2 operator connections:
G4
Open
G5
Close
G6
Common (COM), grey cable
A1 operator connections:
G1
Open
G2
Close
G3
Common (COM), grey cable
Turning direction:
•
When pressing PUL1 (close), DL5 lights up and the A1 G2-G3 and A2 G5-G6
cable connectors are activated.
•
When pressing PUL2 (open), DL4 lights up and the A1 G1-G3 and A2 G4-G6
cable connectors are activated.
If the turning direction is not correct, interchange the cables connected in cable
connectors G1-G2 or G4-G5.
VIVO-M201(M)
Operators of 125 or 230 Vac
We recommend using the
VIVO-M101(M)
switchboard (for single operator installations) and
VIVO-M201(M)
(for twin operator installations).
Содержание ARES AE3324D
Страница 2: ......
Страница 4: ......
Страница 16: ...Actualizado 8 3 16 MANTENIMIENTO Y DIAGN STICO DE AVER AS 12 Manual de instalaci n...
Страница 28: ...Mis jour 9 4 16 MAINTENANCE ET DIAGNOSTIC DE PANNES 24 Manuel d installation...
Страница 40: ...Updated 9 4 16 MAINTENANCE AND DIAGNOSIS OF FAILURES 36 Installation Manual...
Страница 52: ...Actualizado 9 4 16 MANUTEN O E DIAGN STICO DE AVARIAS 48 Manual de instala o...