English
Descripcion_68 v0
.2.fm -
9/4/16
ARES electro-mechanical operator
27
DESCRIPTION OF THE PRODUCT
1
ELEMENTS OF THE COMPLETE INSTALLATION
Fig. 1
Elements of the complete installation
The safe and correct operation of the
installation is the responsibility of the installer.
For greater safety, Erreka recommends installing the
photocells (3) and (8).
INSTALLATION COMPONENTS:
1
Operator
2
Flashing light
3
Exterior photocells
4
Key switch
5
Wall pushbutton
6
Switchboard
7
Connections box
8
Interior photocells
9
Electrolock
10
Stop on closing
11
Antenna
We recommend using the VIVO-M201(M) or VIVO-M101(M) switchboard for the 125/230VAC models
and the VIVO-D201(M) switchboard for the 24VDC models.
ELECTRICAL CABLING:
Element
Nº wires x section
Maximum length
A: Main power supply
3x1.5mm
2
30m
B: Flashing light
2x0.5mm
2
20m
C: Photocells (Tx / Rx)
2x0.5mm
2
/ 4x0.5mm
2
30m
D: Pushbutton or key switch
2x0.5mm
2
25m
E: Operator (125/230 VAC)
4x1mm
2
20m
E: Operator (24VDC)
2x1mm
2
8m (maximum 25m with cable 2x2.5mm
2
)
F: Antenna
Coaxial cable 50
k
(RG-58/U)
5m
Содержание ARES AE3324D
Страница 2: ......
Страница 4: ......
Страница 16: ...Actualizado 8 3 16 MANTENIMIENTO Y DIAGN STICO DE AVER AS 12 Manual de instalaci n...
Страница 28: ...Mis jour 9 4 16 MAINTENANCE ET DIAGNOSTIC DE PANNES 24 Manuel d installation...
Страница 40: ...Updated 9 4 16 MAINTENANCE AND DIAGNOSIS OF FAILURES 36 Installation Manual...
Страница 52: ...Actualizado 9 4 16 MANUTEN O E DIAGN STICO DE AVARIAS 48 Manual de instala o...