Instalacion_68 v0.0.fm
- 9/4/16
INSTALLATION
34
Installation Manual
7
FINAL CHECKS
Checking the closing power
The installation must respect the values
indicated in Standard EN 12453:2000. All
measurements must be made in line with the
method described in Standard EN 12445:2000.
• F
d
< 400N in spaces between 50mm and
500mm
• F
d
< 1400N in spaces> 500mm
User instruction
1
Instruct the user with regards to the use and
maintenance of the installation and provide him/her
with the use manual.
2
Signal the gate, showing that it opens automatically
and indicating how to operate it manually. Where
appropriate, indicate that operation is using the
remote control.
ST
1
FT
1
P1 P2 P3
W
ARNING LIGHT
P9 P10
24V
ST
2
FT
2
P4 P5 P6
ST
O
P
P7 P8
GND
+
G4 G5
GND
N L
SW1
V+
P13
SNG1
P14 P15
SNG2
P16
GND
V+
P17
SNG1
P18 P19
SNG2
P20 P21 P22 P23
ENCODER1
ENCODER2
MOTOR2
G1 G2
GND
MOTOR1
P11 P12
LO
C
K
POWER - 230V
CN1
3
G6
G3
G7 G8
Co
ur
te
sy
Light
Lamp
.
G9 G10
-FT
(Test)
AUX
24 Vdc
P24 P25
EDGE
P144Y2
VIVO-D201:
VIVO-D201M:
A1
Operator 1
A2
Operator 2
G1/G4
Red cable (motor)
G2/G5
Blue cable (motor)
SW1
Main switch
Carry out the following in the VIVO-D201(M) switchboard:
•
Select the number of operators using
C0
(
C001
: one operator,
C002
: two operators).
•
Select the directions using
C1
(A1) and
C2
(A2).
•
Programme
C7
for operation without encoder or limit switches (
C700
).
•
For the ARES 24V operator, programme
C304
.
•
Adjust the thrust in accordance with the weight of the gate (parameter
A6
).
24VDC operators
Turning direction check
: after connecting the power and activating any of the key devices, the
gate makes a reset (the display shows
rS
): the gate closes until it reaches the stopper, assigning this
stopper with the position "gate closed" If it opens instead of closes during the reset, change turning
direction using
C1
(A1) or
C2
(A2).
We recommend switchboard
VIVO-D201(M)
.
Содержание ARES AE3324D
Страница 2: ......
Страница 4: ......
Страница 16: ...Actualizado 8 3 16 MANTENIMIENTO Y DIAGN STICO DE AVER AS 12 Manual de instalaci n...
Страница 28: ...Mis jour 9 4 16 MAINTENANCE ET DIAGNOSTIC DE PANNES 24 Manuel d installation...
Страница 40: ...Updated 9 4 16 MAINTENANCE AND DIAGNOSIS OF FAILURES 36 Installation Manual...
Страница 52: ...Actualizado 9 4 16 MANUTEN O E DIAGN STICO DE AVARIAS 48 Manual de instala o...