ERKA. Aneroid Скачать руководство пользователя страница 7

1. Declaration of guarantee

E

05

Dear Customer,

with this blood pressure gauge you have chosen a quality product from ERKA.

We are delighted that you have shown your confidence in ERKA. quality and we
thank you.

ERKA. instruments meet the valid European standard DIN EN 1060 and are in
accordance with Annex V, Section 3, of the Directive 93/42 EEC dated june 14,
1993. This is certified by the CE-mark on the scale of the instrument. Each blood
pressure gauge has a serial number and is registered accordingly.

The instrument is guaranteed against any material defects which may occur. The

guar

ant

ee doesn’

t

 cover

 i

mpr

oper

 

use, natural wear and tear or outside

interference.
Please ensure that the card is stamped by your dealer.

2. Description of instrument

ERKA. aneroids work according to the auscultatory measuring method Riva Rocci /
Korotkoff.

The necessary pressure in the cuff is created by the inflation bulb. The cuff is
inflated by a few pumpings. The air release valve is sensitively adjustable and
ensures a controlled pressure reduction during the measuring.

The reading scale has a measuring range from 0 - 300 mmHg with a graduation of 2
mmHg. The measuring accuracy over the total measuring range is ± 3 mmHg.

After calibration and a 100 % final control each manometer is sealed against
unauthorised opening.

3. Preparations for measuring

Important! Use the correct cuff-size!

As standard the instrument is supplied with an adult cuff size 13 x 55 cm. This cuff
is suitable for upper arms with a circumference of 29 - 40 cm. For a larger or smaller
circumference the corresponding special sized cuffs should be used. (Please see
chapter 5.)

Fixing the cuff

(general hint)

The cuff must be completely vented before being fixed. It should be tightly fixed to
the left upper arm approx. 2 cm above the elbow joint. The center mark (triangle on
the cuff) must lie on the position of the arteria brachialis.
The arm should be positioned so that the upper part of the cuff is level with the aorta
valve.

Fixing the cuff of home-care instruments

(special hint)

The inflator tubes must point towards the hand. The microphone part of the
stethoscope which is integrated in the cuff must be placed on the arteria. The free
end of the cuff must be drawn through the metal bow and afterwards be closed by
pressing it onto the velcro closure. After that the stethoscope has to be connected
to the microphone part. With this model it is the microphone part and not the center
mark which is placed on the arteria brachialis !

Содержание Aneroid

Страница 1: ...truction manual Mo d ed e mp l o i Instrucciones de manejo I s t r u z i o n i p e r l u s o Aneroid Blutdruckmessger te Aneroid Sphygmomanometers Aneroid Tensiom tres Aneroid Esfigmoman metros Aneroi...

Страница 2: ...ce apr s vente et r talonnage 12 Tabla de materias ES 1 Declaraci n de garant a 13 2 Descripci n del aparato 13 3 Preparaci n de la medici n 13 4 Realizaci n de la medici n 14 5 Elecci n del tama o de...

Страница 3: ...sung von 2 mmHg Die Messgenauigkeit ber den gesamten Messbereich betr gt 3 mmHg Jedes Manometer wird kalibriert gegen unberechtigte Eingriffe gesichert und einer 100 igen Endkontrolle unterzogen 3 Vo...

Страница 4: ...r mit automatischem Ventil Die Handhabung dieses Ger tes ist einfacher und komfortabler Durch Dr cken des Gebl seballs springt der sechseckige Knopf in der Mitte des Ventils heraus Der Messvorgang ist...

Страница 5: ...nschette zuerst die Blase entfernen Bez ge mit Rapidverschluss vor dem Waschen falten so dass Flausch und Hakenband geschlossen aufeinander liegen Alle Metallteile sollen sich innerhalb der Manschette...

Страница 6: ...en als fehlerhaft und m ssen sofort nachkalibriert werden Das Herstellungsjahr des Ger tes l sst sich aus den ersten beiden Ziffern der Seriennummer auf der Skala erkennen F r das Modell Switch ist ei...

Страница 7: ...of 2 mmHg The measuring accuracy over the total measuring range is 3 mmHg After calibration and a 100 final control each manometer is sealed against unauthorised opening 3 Preparations for measuring...

Страница 8: ...of inscribing the various color labels attached refer to item 8 b manometer with automatic valve The handling of this instrument is easier and more comfortable By pumping the bulb the hexagonal button...

Страница 9: ...he cuff the bag must be removed Covers with velcro fastening are to be folded before washing so that the parts of fleece and of hooks are well attached Hints for care Non shrink popelin 100 cotton col...

Страница 10: ...o be recalibrated The date of manufacture is shown by the first two numbers of the serial number A recalibration of the model SWITCH is not intended The faulty manometer housing can be replaced anywhe...

Страница 11: ...n pr muni contre toute op ration non autoris e et soumis un contr le final de 100 3 Pr paration de la mesure Important Choisissez la taille correcte de la manchette Comme standard l appareil est fourn...

Страница 12: ...ge ci jointes sont utilis es b pour tensiom tres valve automatique Le maniement de cet appareil est plus simple et confortable En pressant la poire le bouton hexagonal au centre de la soupape merge Le...

Страница 13: ...e la partie frise et la partie aux petits crochets soient attach es Toutes les parties m talliques doivent tre l int rieur de la manchette Instructions Textile m tisse Coton 100 de lavage couleur vert...

Страница 14: ...res du num ro de s rie sur le cadran P o u rl emo d l eS w i t c hu nr e c a l i b r a g en e s t p a sp r v u D a n sc ec a sl ab o t ed e mesure d fectueuse est directement remplac e sur place par u...

Страница 15: ...g La exactitud de medici n en todo el alcance de medici n es de 3 mmHg Cada man metro es calibrado protegido contra intervenciones no autorizadas y sometido a un riguroso y completo control final 3 Pr...

Страница 16: ...de flecha m nimamente hacia la izquierda m s lento m nimamente hacia la derecha m s r pido Tenga cuidado para que el tornillo de regulaci n no se gire con fuerza m s de lo que los topes derecho e izq...

Страница 17: ...ro Lavar 60 prog ropa delicata 60 prog normal Planchado ajuste tibio normal limpieza en seco como prendas delicadas c prendas normal Secadora tambor con cuidado no es posible Tejido recubierto de PUR...

Страница 18: ...inmediato El a o de fabricaci n del aparato corresponde a las dos primeras cifras del n mero de serie marcado sobre la esfera El modelo Switch no se puede calibrar Cajas medidoras con defecto pueden r...

Страница 19: ...rotetto contro interventi non autorizzati e sottoposto ad un controllo finale completo al 100 3 Preparativi per la misurazione Importante La misura del bracciale deve essere esatta L a p p a r e c c h...

Страница 20: ...c o n f o r t e v o l e P r e me n d ol ap e r a e s c e il pulsante esagonale che si trova nel centro della valvola Si esegue la misurazione come descritto sotto punto 4a Si regola una volta per tutt...

Страница 21: ...ali con chiusura rapid sovrapponendo il nastro peloso soffice a q u e l l o c o n ig a n c e t t i T u t t e l e p a r t ii n me t a l l o d e v o n o t r o v a r s ia l l i n t e r n o d e l braccial...

Страница 22: ...perfetti e devono essere subito ricalibrati Si pu r i l e v a r el a n n od i p r o d u z i o n ed a l l ep r i med u ec i f r ed e l n u me r od i serie sulla scala Per il modello Switch non prevista...

Страница 23: ...20 220 180 180 170 122 Zubeh r Manschette Accessory Cuff Accessoire Manchette Accesorios manguito Accessori bracciale Doppelschlauch Double tube flexible double doble tubo due tubi uniti 1 Schlauch 1...

Страница 24: ...loi et toute op ration nonautoris e Tarjeta de Garantia Concedamos sobre este aparato una garant a de 24 meses Excepci n Perfect Aneroid 36 meses a partis de la fecha de compra que cubre defector de f...

Отзывы: