Example:
/root/>ping 192.168.137.12 12 0x8
6.1.20 PWD
Displays the name of the current directory. PWD is short for Print Working Directory.
Authority: EVERYONE
Syntax:
>pwd
Parameter(s):
Example:
$HL950>pwd
/root/bin
Shows that the present directory is /root/bin. (Setting the system prompt to $path is the
same as issuing this command).
6.1.21 QKEY
Assigns a number key (0-9) to the specified command string. You execute the entire command string
by pressing just the assigned QKEY number.
Authority: ADMIN
Syntax:
>qkey [SET | SHOW] QKEY 0-9, "command string to use", YES |
NO
Parameter(s):
QKEY 0-9
A number between 0 and 9.
YES|NO
Whether to automatically execute the string or not. Default: YES. If you
specify NO, the QKEY will type the string at the prompt and wait for
your input. You must press Enter to run the command string.
Example:
>set qkey 0 “show system modules”, yes
Programs the 0 number key to display the modules installed.
To see QKEY assignments, enter:
/>show qkey
6.1.22 RELOAD
Reloads the HL950, flushes the file systems and logs you off. All uncommitted changes to your
system will be lost. The system prompts you to confirm that you want to execute this command. You
must log back into the HL950 after issuing this command.
Authority: ADMIN
Syntax:
>reload
Parameter(s):
Example:
>reload
Proceed to reload the system (Y/N)?