Multi Service Edge Device HL950
Administrator’s Guide
EN/LZT 108 5995 R3
Page 56 (159)
June 2003
1 packet received after close
0 discarded for bad checksum
0 discarded for bad header offset field
0 discarded because packet too short
2 connection requests
13 connection accepts
15 connections established (including accepts)
14 connections closed (including 1 drop)
0 embryonic connection dropped
1714 segments updated rtt (of 1722 attempts)
9 retransmit timeouts
0 connection dropped by rexmit timeout
0 persist timeout
30 keepalive timeouts
16 keepalive probes sent
0 connection dropped by keepalive
47 pcb cache lookups failed
UDP:
18552 total packets
18499 input packets
53 output packets
0 incomplete header
0 bad data length field
0 bad checksum
14170 broadcasts received with no ports
0 full socket
1 pcb cache lookup failed
0 pcb hash lookup failed
ICMP:
0 call to icmp_error
0 error not generated because old message was icmp
0 message with bad code fields
0 message < minimum length
0 bad checksum
0 message with bad length
0 message response generated
EXECUTED [0]
4.3.8 ROUTE
The DATA ROUTE command is used to display and change the current routes. The following
example shows how to add a default gateway:
HL950> add data route:dest=0.0.0.0, mask=0.0.0.0, gw=67.121.123.100;
NOTE!
If an Ethernet interface is set to DHCP, its type must be set to WAN for the default
gateway to be applied;
set interface data ethernet if=eth0, type=wan
Display the details of a specified route:
HL950> show data route:dest=192.168.0.1;
Destination Mask TOS Gateway Flags RefCnt Use Interface Proto
0.0.0.0 0 0 172.18.40.1 3 1 1898 eth1 1
127.0.0.1 0 0 127.0.0.1 5 0 0 lo0 0
172.18.40.0 fffff800 0 172.18.40.113 101 0 0 eth1 0
192.168.0.0 fffff800 0 192.168.2.190 101 0 0 eth0 0