6.8.9 MODULES
Used to display information about modules currently installed and to control message levels.
Authority: EVERYONE
Prefixes
Parameters and Descriptions
SET
SHOW
START
NAME<STR>
:
Specifies the name of the module to which the change of message level
applies.
LEVEL<STR>
:
Specifies the message level. Valid values are NONE, MISC (shows both
APP and SYS messages), TRACE (minimum amount of debug detail), DEBUG (maximum
amount of debug detail), and ALL
6.8.10 SHELL
Used to control the Command Line Interpreter for various shell sessions.
Authority: ADMIN
Prefixes
Parameters and Descriptions
SET
SHOW
PROMPT<STR>
:
Any string you specify up to 31 characters (all characters are valid, but
spaces are not). Or specify one of the following special prompts:
$path – shows the current path
$sysname – shows the system name
$ip – shows the primary IP address
WIDTH<NUM>
:
Width of the terminal. Default: 80
TIMEOUT<NUM>
:
Inactivity logoff in minutes. 0=disabled
RETRIES<NUM>
:
Number of invalid logon attempts before locked. 0=disabled
DELAY<NUM>
:
Delay in minutes for exceeding retries. 0=disabled
HL950> show system shell
MSED Shellv2 Settings:
Prompt: $ip
Width: 80
Timeout: 15 (mins)
Retries: 3 (mins)
Delay: 15 (mins)
[EXECUTED]
NOTE!
When the prompt appears between asterisks (*prompt*), your system has unsaved changes.
Use the
SAVE
command to write the changes to non-volatile memory (at which point the
prompt returns to normal – that is, without asterisks).