11.6.6.1 line
Use this command to configure the EXN104 lines.
Command level:
ecn330(config)#.
Syntax
exn <
node
> line <
line
> {state {enable|disable}|sync
{master|slave}|test {disable|line-loop}}
Arguments:
•
exn <
node
>
-
EXN104 node no. in the format
a.b
•
line <
line
>
–
The line no. in the range 1 to 4
•
state enable/disable
- Enable or disable the operational
state of the EXN104 line.
•
sync master/slave
- Set the synchronisation mode of the line
to master or slave
•
test disable/line-loop
- Disable the line-loop test mode or
enable the line-loop test mode.
Default Setting
None.
Command Usage
The command is used to configure the EXN104.
Example
ecn330(config)#
exn 3.100 line 3 state enable
ecn330(config)#
exn 3.100 line 3 sync master
ecn330(config)#
exn 3.100 line 3 test line-loop