Troubleshooting
168
1553-CNH 160 0787 Uen PA2 2005-09-23
13.4 CLI
Table 24
Troubleshooting Chart
Symptom Action
Cannot connect using Tel-
net or SNMP software
Be sure the agent is configured with a valid IP address, subnet mask
and default gateway.
If trying to connect to the agent using the IP address for a tagged
VLAN group, the management station must include the appropriate tag
in its transmitted frames.
Check that there is a valid network connection to the switch and that
the port being used has not been disabled.
Check network cabling between the management station and the
switch.
If a Telnet session cannot connect, the switch may have exceeded the
maximum number of concurrent Telnet sessions permitted. Try con-
necting again at a later time.
Cannot access the on-
board configuration pro-
gram through a serial port
connection
Be sure the terminal emulator program is set to VT100 compatible, 8
data bits, 1 stop bit, no parity and 9600 bps.
Check that the null-modem serial cable conforms to the pin-out con-
nections provided in section 2.2.5 on page 6.
Содержание ECN320
Страница 1: ...ECN330 and ECN320 User Guide...
Страница 27: ...ECN Functions Features and HW 1553 CNH 160 0787 Uen PA2 2005 09 23 19 Figure 6 Fan Tray...
Страница 60: ...Web interface 52 1553 CNH 160 0787 Uen PA2 2005 09 23 Figure 29 Lines Overview...
Страница 62: ...Web interface 54 1553 CNH 160 0787 Uen PA2 2005 09 23 Figure 31 Alarm Log...
Страница 173: ...Using a MIB Browser 1553 CNH 160 0787 Uen PA2 2005 09 23 165 Figure 46 Querying VLAN ID...
Страница 187: ......
Страница 188: ...Ericsson AB Ericsson AB 2005 All Rights Reserved www ericsson com 1553 CNH 160 0787 Uen PA2 2005 09 23...