Command Line Interface
128
1553-CNH 160 0787 Uen PA2 2005-09-23
•
line-type esf/d4/e1/e1crc/auto-crc
– Insert the line
type of the EXN104 lines.
−
esf
Extended SuperFrame DS1 (T1.107)
−
d4
AT&T D4 format DS1 (T1.107)
−
e1
ITU-T Recommendation G.704 (Table 4a)
−
e1crc ITU-T Recommendation G.704 (Table 4b)
−
auto-crc Set the E1 line to use auto negotiations on CRC
(G.706)
Default Setting
None
Command Usage
The command will set the line type of the E1 line of the EXN104 FE to E1
converter.
Example
ecn330(config)#
exn 3.100 line-type e1
11.6.7 load-configuration
Use this command to roll back to the last saved configuration.
Command level:
ecn330(config)#.
Syntax
load-configuration
Arguments:
•
load-configuration –
Load the last saved configuration.
Default setting
None