![Epson VT Series Скачать руководство пользователя страница 253](http://html.mh-extra.com/html/epson/vt-series/vt-series_manipulator-manual_110813253.webp)
Maintenance 18. Controller Unit
VT Rev.1
237
CPU/DPB Board
Installation
(1) Attach the thermal sheet on the surface (the side with no
connectors) of the new CPU/DPB board
Make sure not to attach the sheet on the wrong surface.
Thermal sheet
(2) Mount the CPU/DPB board and fix it by the mounting screws.
Binding head screws: 5-M3×6
Tightening torque: 0.45 ± 0.1N·m
(3) Connect the CPU/DPB board connectors.
E: Power connector (IN/OUT
×
1 for each)
F: Cooling fan connector
G: Regenerative resistor connector 1
H: Regenerative resistor connector 2
Be careful not to connect the wrong connectors or forget to
connect it.
F
G
H
E-OUT E-IN
(4) Mount the power board.
Reference:
Maintenance 18.2 Replacing Power Board
NOTE
NOTE
Содержание VT Series
Страница 1: ...6 Axis Robots VT series MANIPULATOR MANUAL Rev 1 EM18YR3817F ...
Страница 2: ...MANIPULATOR MANUAL VT series Rev 1 ...
Страница 8: ...vi VT Rev 1 ...
Страница 16: ...TABLE OF CONTENTS xiv VT Rev 1 ...
Страница 18: ......
Страница 31: ...Setup Operation 2 Specifications VT Rev 1 15 2 4 Outer Dimensions ...
Страница 32: ...Setup Operation 2 Specifications 16 VT Rev 1 Unit mm ...
Страница 33: ...Setup Operation 2 Specifications VT Rev 1 17 2 5 Standard Motion Range Unit mm ...
Страница 129: ...Maintenance This volume contains maintenance procedures with safety precautions for VT series Manipulators ...
Страница 130: ......
Страница 138: ...Maintenance 3 Manipulator Structure 122 VT Rev 1 3 Manipulator Structure ...