Maintenance 7. Covers
146
VT Rev.1
7.7 Connector Plate
CAUTION
■
Do not remove the connector plate forcibly. Removing the connector plate
forcibly may result in damage to the cables, disconnection, and/or contact failure.
Damaged cables, disconnection, or contact failure is extremely hazardous and
may result in electric shock and/or improper function of the robot system.
■
When installing the connector plate, be careful not to allow the cables to interfere
with the plate mounting and do not bend these cables forcibly to push them into
the cover.
Unnecessary strain on cables may result in damage to the cables, disconnection,
and/or contact failure. Damaged cables, disconnection, or contact failure is
extremely hazardous and may result in electric shock and/or improper function of
the robot system.
When routing the cables, observe the cable locations after removing the
connector plate. Be sure to place the cables back to their original locations.
Connector Plate
10-M4
×
10
Connector
Plate
Removal
(1) Remove the Power Cable Cover.
Refer to
Maintenance: 7.6 Power Cable Cover.
(2) Remove the power cable clamp and then remove Power Cable Connector.
When removing the Power cable connector, pull it out with pushing latches
on both side of the connector.
(3) Unscrew the Connector Plate mounting bolts and then remove the Connector Plate.
Connector
Plate
Installation
(1) Put the Connector Plate to the base and secure using the mounting bolts.
Hexagon socket head cap button bolt: 10-M4
×
10
Tightening torque: 4.0
±
0.2 N·m
(2) Connect the Power Cable Connector and install the power cable clamp.
(3) Mount the Power Cable Cover.
Refer to
Maintenance:
7.6 Power Cable Cover.
NOTE
Содержание VT Series
Страница 1: ...6 Axis Robots VT series MANIPULATOR MANUAL Rev 1 EM18YR3817F ...
Страница 2: ...MANIPULATOR MANUAL VT series Rev 1 ...
Страница 8: ...vi VT Rev 1 ...
Страница 16: ...TABLE OF CONTENTS xiv VT Rev 1 ...
Страница 18: ......
Страница 31: ...Setup Operation 2 Specifications VT Rev 1 15 2 4 Outer Dimensions ...
Страница 32: ...Setup Operation 2 Specifications 16 VT Rev 1 Unit mm ...
Страница 33: ...Setup Operation 2 Specifications VT Rev 1 17 2 5 Standard Motion Range Unit mm ...
Страница 129: ...Maintenance This volume contains maintenance procedures with safety precautions for VT series Manipulators ...
Страница 130: ......
Страница 138: ...Maintenance 3 Manipulator Structure 122 VT Rev 1 3 Manipulator Structure ...