Item
Parameter
Explanation
Media Adjust
Select this option to adjust media with
Auto Media Adjust
disabled or
make readjustment when changing printing conditions after saving
media settings.
In this menu, perform
Feed Adjustment
and
Head Alignment
individually.
Adjustment types and execution procedure
U
Feed Adjustment
Auto
Manual
Head Alignment
Standard
(Auto)
Standard
(Manual)
Block pattern
Manual(Uni-D)
Manual(Bi-D)
Manual(Dual Head)
*1
Heating & Drying
Heater Tempera-
ture
Pre-heater/platen
heater: 30˚C to 50˚C
(86˚F to 122˚F)
After heater: 30˚C to
55˚C (86˚F to 131˚F)
The temperatures for the pre-, platen, and after heaters can each be
adjusted separately.
Drying Time Per
Pass
0 to 10 sec
Select the time the print head pauses to allow drying after each pass.
Choose from values between 0.0 and 10.0 seconds. The time needed for
the ink to dry varies with ink density and the media used. If the ink blurs on
the media, set a longer time for drying the ink.
Increasing the drying time increases the time needed to print.
After Heater Feed
Mode 1
To feed media to the after heater after printing, choose
Mode 1
or
Mode 2
;
otherwise, choose
Off
.
If
Mode 1
is selected, the portion fed for drying will not be rewound before
the next job starts. Select this option if the media will be cut before the next
job starts.
If
Mode 2
is selected, the portion fed for drying will be rewound before the
next job starts, eliminating unnecessary margin. Select this option if
multiple jobs will be printed consecutively.
Mode 2
Off
Additional Dryer
On
This item is displayed only when the additional print drying system
(supplied with the SC-S50600 series; optional with other models) is
installed.
Select
On
to enable, or
Off
to disable, the additional print drying system
(supplied with the SC-S50600 series; optional with other models). Note
that even when
On
is selected, the additional print drying system will turn
off with the heaters when the Heat Off Timer expires. The additional print
drying system will turn back on when the heaters resume operation. Heat
Off Timer
U
“The Printer Setup Menu” on page 149
Off
Advanced Settings
During general use, use the default setting value without changing it.
When using special media or when a problem such as head striking or
banding is detected in printing results, change the default.
EPSON SC-S70600 series/SC-S50600 series/SC-S30600 series User's Guide
Using the Control Panel Menu