Rev. A
Handling 3-13
EU-T532/T542 Technical Manual
Confidential
Possible recovery error
Recovery impossible error
Note:
When any error shown above occurs, turn off the power as soon as possible.
Table 4-7 Possible Recover Error
Error type
LED flashing pattern
Cause
Platen open error
Platen unit is open during printing.
Autocutter error
Autocutter malfunction
Black mark sensor
detection error
No black mark is detected even after a certain amount
of paper with black mark is fed.
Presenter error
A paper jam has been detected in the cut sheet
presenter module.
Table 4-8 Impossible recover error
Error type
LED flashing pattern
Cause
CPU execution error
The CPU executes an incorrect address.
R/W error in
memory or G/A
After R/W checking, the printer does not work correctly.
High voltage error
The power supply voltage is extremely high.
Low voltage error
The power supply voltage is extremely low.
PCB connection
error
The printer is not connected or the head wiring is
disconnected.
Approx. 5.12 s
Approx. 320 ms
Approx. 320 ms
Approx. 5.12 s
Approx. 5.12 s
Approx. 5.12 s
Approx. 320 ms
Approx. 5.12 s