Install the sauna heater and the vaporizer
in front of the air intake according to the
manufacturer’s installation instructions.
Run the silicone line through the ductwork
to the power unit and connect it to the ap-
propriate terminals as directed in the wiring
diagram.
Note:
In case there is no ductwork available
drill a hole next to the air intake opening and
run the heater line through this hole to the
outside and to the appropriate terminals in
the control unit.
The silicone line must be
buried to protect it from outside infl uences.
Therefore, use a suitable cable-duct or a
PVC-pipe through which you can run the line
up to the power unit.
Electrical connection
The electrical connection may only be
done by a certifi ed electrician in compli-
ance with the guidelines of the local utility
company and the VDE.
In general, there may be only one fi xed con-
nection to the network; therefore equipment
should be provided that makes it possible
to disconnect the system with all poles from
the network with a contact opening width of
minimum 3 mm.
All electrical installations and all connection
lines that are installed inside the cabin must
be suitable for ambient temperature of at
least 170 °C.
The power supply line is run to the load con-
trol unit and connected to the power input
terminals.
Connecting the sauna he-
ater