9
GB
Control element
Fig. 7
Inside wall of
cabin
Outside wall of
cabin
Insulation
Control line
The control line may only be laid between
the insulation and the outside wall of the ca-
bin (Fig. 7).
(The insulation must be designed for max.
outside temperature of 75 °C.)
Laying the control line
Assembly
The control element may only be mounted
outside the cabin. It is advisable to select the
outside wall of the cabin. If ductwork is alrea-
dy provided for electrical installations then
the position of the control element is prede-
termined by that. The installation is done into
the cabin wall. Please follow the instructions
for installation:
13
5
13
7
min. 300
155
187
ca. 200
Fig. 6
Defi ne the exact installation site. Pay attenti-
on to the sizes shown in Fig. 6.
Make sure that there are no lines or
construction parts of the cabin that could be
damaged in the installation area.
Use the supplied drill template to produce
the wall cutout (Print No. 2934 3845).
Attach the drill template to the cabin wall and
cut out the wall opening. Pay close attention
to the dimensional accuracy.
Fig. 8
Now lead the control line through the ope-
ning of the protective housing.
Plug the plug on the control line into the
socket on the power element (Figs. 8 and
8a) until it automatically locks into place. It
is now secured against unintentional loose-
ning.