Error Message
In order to show you an immediate diagnosis when a possible error occurs, the following
errors may be defi ned on the display through the error code.
Error code
Error description
E 100
Temperature sensor fault (no
signal)
E 101
Temperature sensor short cir-
cuit
E 103
Bench sensor (optional 2
nd
sensor) fault (no signal)
To acknowledge the error report after water
shortage fi ll water into vaporizer fi rst.
Be careful. The unit parts may be hot and
heavy steam may occur.
!!!Danger of scal-
ding!!!
By touching the
symbol for ca. 3 seconds
you will start the unit again.
Remedy
Check the lines or sensors
The respective sensor has approx. 1.9
kW
at a room temperature of 20°. Exchange the
sensor if necessary.
Please contact your dealer.
E 104
Bench temperature sensor
(optional 2
nd
sensor) short cir
cuit
E 111
Interruption or short in humi-
tysensor
Check lines, replace sensor if necessary.
To be able to use your sauna you may deac-
tivate the humidity sensor.
To do that touch the following buttons:
E 211
Overheating limiter fault (no
signal or blown fuse)
E 510
Water shortage – refi ll period
E 511
Water shortage – refi ll period
exceeded
Refi ll water
Check lines or thermal fuse. Thermal fuse =
142°C