InfraStyle / InfraStyle i - Installation Instructions
21
Installation
Line routing
The lines from the individual components to the power unit may not
exceed 5.5 m in length.
If you connect more than one emitter per heating circuit, you must termi-
nate the corresponding lines in the on-site plug-in modules outside the
relay box. See
Example – plug-in modules (optional),
The control line must only be routed between the insulation and the outer
wall of the cabin. Cabin insulation must be installed in such a way that the
temperature in the area in which cables are routed cannot exceed 75°C.
Extending the control panel's control line
For longer connections, special RJ10/RJ14 connecting cables with lengths
of 10 m, 25 m, 50 m and 100 m are available as an option.
Alternately, the supplied (as standard) 5-m line can also be extended with
an RJ12/RJ12 coupling and an RJ12/RJ12 extension cord.
The extensions and couplings are available as options.
See Accessories (optional),