Installation Instructions - InfraStyle / InfraStyle i
Installation
EN
Advanced installation
A maximum of 2 infrared modules may be connected to the
InfraStyle relay box in an advanced installation.
IR relay box with connected IR modules
For control purposes, the relay box and module are identified by unit
addresses.
Bus communication can be adversely affected if the cabin is equipped with
too many add-on modules. If this is the case, the control panel will display
the following error message: No bus communication.
To rectify the problem, ensure the modules have their own power supplies.
The power supply must be mounted separately from the relay box and, just
like the relay box, outside of the cabin.
A
Relay box (unit 1)
B
IR module (unit 2)
C
IR module (unit 3)
3
3
3
3
3
3
230 V AC 50 Hz
3
IR-Emitter 1
IR-Emitter 2
IR-Emitter 3
3
3
3
3
230 V AC 50 Hz
IR-Emitter 7
IR-Emitter 8
IR-Emitter 9
3
3
3
3
230 V AC 50 Hz
IR-Emitter 4
IR-Emitter 5
IR-Emitter 6
C
A
B