InfraStyle / InfraStyle i - Installation Instructions
27
Installation
4.3 Relay box
The relay box must only be mounted outside of the cabin. Observe the fol-
lowing guidelines.
4.3.1 Guidelines
DANGER
Risk to life and limb and risk of fire
Risk to life and limb from electric shock and fire in the event of im-
proper or faulty electrical connection. This risk also applies follow-
ing completion of the installation work.
Do not install relay boxes in enclosed cabinets or wood panel-
ling.
Proper and improper relay box installation
Recommended installation sites are:
Outer wall of the cabin
Utility room
If empty conduits for electrical installations are already present, this dic-
tates the position of the relay box.
All lines should be routed before installing the relay box. Connections can
be established later. Data lines must be routed and connected in such a
way that they are not openly accessible.