58
Installation Instructions - InfraStyle / InfraStyle i
Installation
EN
5.4 Connecting data lines
NOTICE
Equipment damage due to improper installation
Additional modules with a safety temperature limiter can be
mounted in a cabin.
Connect the safety temperature limiter only to the relevant
module.
Never connect more than one safety temperature limiter to a
module.
Always connect the safety temperature limiter as an isolated
contact.
Connecting data lines
1
DANGER! Ensure that the relay box is current-free.
Open the housing.
2
Route the line through the openings at the base or on the back of the
housing.
3
Plug the S-Bus line RJ10/RJ14 from the control panel into the free jack
RJ14 (S-BUS).
A
RJ14 plug from control panel
B
RJ10 plug for sensor line
C
Power supply connection
D
Temperature sensor
E
Safety temperature limiter
F
Jumper at safety temperature limiter
terminal
A
C
B
S-Bus
STB
Sensor
RJ
10
RJ
14
RJ
10
RJ
14
Sensor
D
E
F