InfraStyle / InfraStyle i - Installation Instructions
59
Installation
4
Plug the sensor line from the temperature sensor into the free jack RJ10
(SENSOR).
The connected sensor is automatically recognised and configured by
the control panel.
Connect shielding of the line to ground if necessary.
5
Check if there is a jumper at the safety temperature limiter terminal.
By default, the safety temperature limiter terminal is jumpered at the
relay box circuit board. A safety temperature limiter is not needed for
an IR-only installation, since temperatures above 70°C cannot be
reached by the IR emitters.