26
Step 6.
(Optional) If you plan on using facing material that has a total thickness greater than 7/8 inch
then facing extensions are required. Remove existing facing flanges and replace them with the
supplied extensions using a T-20 screwdriver.
Initial Installation
QUALIFIED INSTALLERS ONLY
Step 7.
Install the supplied non-combustible facing board with eight (8) supplied 8-32 x.75 fasteners
and a 1/4 inch socket. These screws can be found in the manual bag, remove them and install
the board. Line up the holes and drill fasteners into the board until the screw head is flush with
facing board.
CAUTION: DO NOT DRILL INTO THE BOARD ANY FURTHER OR IT MAY
CRACK.
This board is mandatory, if it is damaged contact you ENVIRO dealer.
Figure 40: Standoff Brace Install
Figure 41: Standoff Brace Install
A
DETAIL
A
SCALE
1 : 5