30
Initial Installation
QUALIFIED INSTALLERS ONLY
Cool Surface System (CSS) Install: Image
shows the short finishing edge,
combustible
can be brought right down to the finishing edge.
Standard Install: the Non-combustible is
mandatory. Image shows single layer finishing
material using the short finishing edge.
Standard Extended Install: Using the supplied
long finishing edge,
non-combustible material
may be layered on top of the supplied Non-
combustible board. Supplied board not needed
for thick non-combustible
finishes like rock.
Cool Surface System Extended Install: Using
the supplied long finishing edge,
combustible
material may be layered on top of the supplied
Non-combustible board. Supplied board is not
needed for thicker combustible
finishes.
1
2 "
13mm
7
8 "
22mm
Mimimum
Supplied
Non
Combustible
Board
Ex. Shiplap
Extended
Tiling Flange
1
2
"
13mm
Drywall
7
8 "
22mm
Mimimum
13 38 "
341mm
Supplied
Non
Combustible
Board
Extended
Tiling Flange
1
2 "
13mm
Supplied
Non
Combustible
Board