Wall Mounted Object
Initial Installation
QUALIFIED INSTALLERS ONLY
Figure 49: Option 2
Option 2: Open Chase (built-out installations) -
This could be considered the most discreet option
when considering the CSS. The chase must be constructed in a way that stops short of the ceiling, leaving
it totally vented above. Minimum framing dimensions must be followed when constructing this option and
not to deviated from them when using combustible materials. Consider
Optional 3: Valance
to work in
conjunction with this option.
Option 3: Valance -
A valance may be desired to accentuate or hide the CSS outlet. Consider framing
option 1 or 2 to utilize the valance feature. This is an optional decorative feature that covers up the CSS
outlet gap. Minimum opening and valance dimensions must be followed to ensure safe heat dissipation.
Combustible materiel is acceptable when constructing the valance. It is acceptable to wrap the valance
around the three sides of a built out chase (Option 2).
Figure 52: Valance Iso View
2" MIN
Figure 51: Valance Install
Figure 50: Open Chase Iso View
3"
76mm
Minimum
5"
127mm
Minimum
6"
152mm
Minimum
Wall Mounted Object
3”