Chapter 6
Troubleshooting & Repairs
6-4
9307
Printer Power Failure
RVM not operational
Contact Envipco Support
Printer does not have adequate
power.
Check the printer harness.
9308
Printer No Response
RVM not operational
Contact Envipco Support
Printer communications error.
Check the printer harness.
9309
Printer Not connected or wrong
Interface Setting
RVM not operational
Contact Envipco Support
Printer communications error.
Check the printer harness.
9310
Printer Print Receipt failed
RVM not operational!
Call Staff
Printer cannot print a receipt.
Check the printer harness. Clean print head.
9500
RVM is in Error Mode
RVM not operational
Contact Envipco Support
This is a catch-all
RVM
error.
Inspect all components and harnesses.
9700
Feed Ctrl Error
Contact Envipco Support
General In-Feed error
Check for jams. Inspect the harnesses. Test
the In-Feed Actuators with the Diagnostic
Program (Ultra-48 / Service Mode).
9701
Feed Ctrl Error
Hardware Init failed
Contact Envipco Support
In-Feed error found on hard-
ware initialization.
Check for jams. Inspect the harnesses. Test
the In-Feed Actuators with the Diagnostic
Program (Ultra-48 / Service Mode).
9702
Feed Ctrl Error
Elevator failed
Contact Envipco Support
In-Feed elevator isn’t working.
Check for jams. Inspect the harnesses. Test
the In-Feed Actuators with the Diagnostic
Program (Ultra-48 / Service Mode).
9703
Feed Ctrl Error
Sorter failed
Contact Envipco Support
The Sorting Cylinder won’t go
into index position. The Sort-
ing Cylinder is probably
jammed.
Check that the Sorting Cylinder can turn
without obstruction: The assembly may have
come out of alignment. Test the Sorting Cyl-
inder using Diagnostic Program (Ultra-48 /
Service mode / Sorter).
9704
Feed Ctrl Error
Light Sensor 1
Contact Envipco Support
Retro-reflector materials sen-
sor failure.
Clean sensor lens and reflector. Calibrate sen-
sor. Test the sensor with the Diagnostic Pro-
gram (Ultra-48 / Sensors).
9705
Feed Ctrl Error
Light Sensor 2
Contact Envipco Support
Retro-reflector materials sen-
sor failure.
Clean sensor lens and reflector. Calibrate sen-
sor. Test the sensor with the Diagnostic Pro-
gram (Ultra-48 / Sensors).
9706
Feed Ctrl Error
Light Sensor 3
Contact Envipco Support
Retro-reflector materials sen-
sor failure.
Clean sensor lens and reflector. Calibrate sen-
sor. Test the sensor with the Diagnostic Pro-
gram (Ultra-48 / Sensors).
9707
Feed Ctrl Error
Light Sensor 4
Contact Envipco Support
Retro-reflector materials sen-
sor failure.
Clean sensor lens and reflector. Calibrate sen-
sor. Test the sensor with the Diagnostic Pro-
gram (Ultra-48 / Sensors).
TABLE 6-1.
ULTRA Error Messages
Error# Error Message
Cause
Troubleshooting
Содержание U48DFF
Страница 1: ...ULTRA Series Service Manual May 6 2014...
Страница 2: ......
Страница 16: ...Chapter 1 Introduction Safety 1 8 FIGURE 1 9 Pinch Point Label Locations Rear Access Panel Pinch Point Labels...
Страница 18: ...Chapter 2 Specifications 2 2 FIGURE 2 2 ULTRA 48 Configuration...
Страница 27: ...3 5 Sensor Tunnel FIGURE 3 4 Sensor Tunnel Left Side View FIGURE 3 5 Sensor Tunnel Right Side View...
Страница 40: ...Chapter 3 Hardware Components 3 18 FIGURE 3 17 MC1 Board Layout FIGURE 3 18 MC5 Board Layout...
Страница 41: ...3 19 RVM Controller Box FIGURE 3 19 MD5 Board Layout...
Страница 52: ...Chapter 4 RVM Software 4 6 FIGURE 4 6 Service Mode Time Out Screen...
Страница 68: ...Chapter 4 RVM Software 4 22 FIGURE 4 18 Software Processes Overview...
Страница 69: ...4 23 Software Theory of Operation FIGURE 4 19 Circuit Board Locations...