Chapter 6
Troubleshooting & Repairs
6-2
9009
Left Bin Door open
Safety breach!
RVM not operational
Close all Doors!
Left Bin Door is open.
Make sure that all doors are closed. If the
doors are closed, check the Diagnostic Pro-
gram (Main / Safety Loop) to see what is
causing this error.
9011
Right Bin Door open
Safety breach!
RVM not operational
Close all Doors!
Right Bin Door is open.
Make sure that all doors are closed. If the
doors are closed, check the Diagnostic Pro-
gram (Main / Safety Loop) to see what is
causing this error.
9014
Emergency cutout!
RVM not operational!
MC
1 triggered an emergency
shutoff.
9015
24
V
Power Fail
There is a problem with the
24
V
150
W
power supply in the
RVM
Controller Box.
9016
Breaker Compactor1 triggered
RVM not operational
Contact Envipco Support
The Variable Speed Drive for
Compactor 1 went into over-
load and shut down the
AC
compactor power.
If this error persists, there may be a problem
with the compactor or the
AC
motor.
9017
Breaker Compactor2 triggered
RVM not operational
Contact Envipco Support
The Variable Speed Drive for
Compactor 2 went into over-
load and shut down the
AC
compactor power.
If this error persists, there may be a problem
with the compactor or the
AC
motor.
9018
Compactor 1 jammed
RVM not operational
Contact Envipco Support
The
RPM
sensor on compactor
1 detected that the compactor
stalled. It is probably a jam.
Clear the compactor jam.
9019
Compactor 2 jammed
RVM not operational
Contact Envipco Support
The
RPM
sensor on compactor
2 detected that the compactor
stalled. It is probably a jam.
Clear the compactor jam.
9022
No Printer Client
RVM not operational
Contact Envipco Support
The Printer Process is not run-
ning on the
PC
board.
Check harnesses and connections. If that
fails, replace the
RVM
controller.
9023
No Display Client
RVM not operational
Contact Envipco Support
The Display Process is not run-
ning on the
PC
board.
Check harnesses and connections. If that
fails, replace the
RVM
controller.
9024
Hardware Init
-> Emergency cutout
RVM not operational
Contact Envipco Support
MC
1 triggered the safety inter-
lock during hardware initializa-
tion.
9025
Initialization failed
Make sure Sorter and Infeed are
free
RVM not operational
Contact Envipco Support
MC
5 initialization could not
complete for some reason.
Either the Sorting Cylinder or
In-Feed is jammed.
Clear any jams in the In-Feed or Sorting Cyl-
inder.
TABLE 6-1.
ULTRA Error Messages
Error# Error Message
Cause
Troubleshooting
Содержание U48DFF
Страница 1: ...ULTRA Series Service Manual May 6 2014...
Страница 2: ......
Страница 16: ...Chapter 1 Introduction Safety 1 8 FIGURE 1 9 Pinch Point Label Locations Rear Access Panel Pinch Point Labels...
Страница 18: ...Chapter 2 Specifications 2 2 FIGURE 2 2 ULTRA 48 Configuration...
Страница 27: ...3 5 Sensor Tunnel FIGURE 3 4 Sensor Tunnel Left Side View FIGURE 3 5 Sensor Tunnel Right Side View...
Страница 40: ...Chapter 3 Hardware Components 3 18 FIGURE 3 17 MC1 Board Layout FIGURE 3 18 MC5 Board Layout...
Страница 41: ...3 19 RVM Controller Box FIGURE 3 19 MD5 Board Layout...
Страница 52: ...Chapter 4 RVM Software 4 6 FIGURE 4 6 Service Mode Time Out Screen...
Страница 68: ...Chapter 4 RVM Software 4 22 FIGURE 4 18 Software Processes Overview...
Страница 69: ...4 23 Software Theory of Operation FIGURE 4 19 Circuit Board Locations...