Cambridge Pellet Stove Installation and Operation Manual
67
13
BLOWER REPLACEMENT
13.1
Convection blower
Before disconnecting the wire harness from the convection fan assembly, take note which wire goes
where.
1.
Remove the decorative panel on the right hand side. Then, Remove the two screws
(A)
that hold
the panel at the back of the stove. Open and lift the panel to take it off the stove.
2.
Remove the wing nut
(I)
that holds the convection blower
(K)
in place. Pull on the blower to take it
out of the stove.