6
Cambridge Pellet Stove Installation and Operation Manual
1
CAMBRIDGE GENERAL INFORMATIONS (EP00075)
1.1
Appliance performance
(1)
Fuel type
Wood Pellet (Premium grade or better)
(
☨
)
Recommended heating area
[*]
500 to 2,200 ft
2
(46 to 185 m
2
)
Hopper capacity
60 lb (27 kg)
Maximum burn time
[*]
50 h
Maximum heat input rate
(2)
43,000 BTU/h (12.6 kW)
Overall heat output rate (min. to max.)
(3)
6,400 BTU/h to 29,300 BTU/h (1.9 kW to 8.6 kW)
Average overall efficiency
(3)
69.8% (HHV
(4)
)
75.3% (LHV
(5)
)
Optimum efficiency
(6)
77.2%
Burn rate
1.2 lb/h to 5.0 lb/h (0.5 kg/h to 2.3 kg/h)
Average particulate emissions rate
(7)
2.9 g/h (EPA / CSA B415.1-10)
Average CO
(8)
41.2 g/h
Average electrical power consumption
(9)
3.5A (420W) for ignition cycle
2.3A (276W) min. / 3.1A (372W) max. for continuous
operation
[*]
Recommended heating area and maximum burn time may vary subject to location in home, chimney draft, heat
loss factors, climate, fuel type,
feed rate, fuel level,
and other variables. The recommended heated area for a given
appliance is defined by the manufacturer as its capacity to maintain a minimum acceptable temperature
considering that the space configuration and the presence of heat distribution systems have a significant impact in
making heat circulation optimum.
(
☨
)
Grades of pellet fuel are determined by organizations such as Pellet Fuels Institute (PFI), ENplus and CANplus.
(1)
Values are as measured per test method, except for the recommended heating area, hopper capacity, maximum
burn time and maximum heat input rate. Results may vary depending on pellet quality, density, length, and
diameter.
(2)
Based on the maximum burn-rate and a dry energy value of pellet at 8,600 BTU/lb.
(3)
As measured per CSA B415.1-10 stack loss method.
(4)
Higher Heating Value of the fuel.
(5)
Lower Heating Value of the fuel.
(6)
Optimum overall efficiency at a specific burn rate (LHV).
(7)
This appliance is officially tested and certified by an independent agency.
(8)
Carbon monoxide.
(9)
Unless stated otherwise, measures were taken directly at the main power source and include all electrical
components present in the appliance.
Содержание Cambridge EP00075
Страница 64: ...64 Cambridge Pellet Stove Installation and Operation Manual 10 WIRING DIAGRAM ...
Страница 72: ...72 Cambridge Pellet Stove Installation and Operation Manual 15 EXPLODED VIEW AND REPLACEMENT PARTS ...
Страница 73: ...Cambridge Pellet Stove Installation and Operation Manual 73 ...
Страница 74: ...74 Cambridge Pellet Stove Installation and Operation Manual ...
Страница 75: ...Cambridge Pellet Stove Installation and Operation Manual 75 ...
Страница 76: ...76 Cambridge Pellet Stove Installation and Operation Manual ...
Страница 77: ...Cambridge Pellet Stove Installation and Operation Manual 77 ...
Страница 78: ...78 Cambridge Pellet Stove Installation and Operation Manual ...
Страница 79: ...Cambridge Pellet Stove Installation and Operation Manual 79 ...