Cambridge Pellet Stove Installation and Operation Manual
19
United States:
•
Not Less than 36
"
(91 cm) above any forced air inlet located within 120
"
(305 cm);
•
Not Less than 48
"
(122 cm) below and horizontally from, or 12
"
(30 cm) above, any door, window
or gravity air inlet into any building;
•
Not Less than 24
"
(61 cm) from an adjacent building and not less than 84
"
(213 cm) above grade
when located adjacent to a public walkway;
•
Cannot be located less than 12
"
(30 cm) above grade;
•
Cannot be located above a gas meter/regulator within 36
"
(91cm) horizontally of the vertical
center line of the regulator;
•
Not within 6 feet (183 cm) of a gas service regulator vent outlet;
•
Other restrictions may apply. See NFPA 211 for further information.
4.4.1.1
Direct Vent System (2-in-1 Exhaust and fresh air intake)
In Canada:
The permitted termination location for a direct vent system are the same than those
permitted with a regular pellet vent system.
In the Unites States :
The permitted termination location for a direct vent system are the same than
those permitted with a regular pellet vent system except for the following : The exit terminal shall be
located not less than 9" (23 cm) from any opening through which vent gases could enter a building.
4.5
Installation Configurations
4.5.1
Installation Warnings, Cautions and Recommendations Reminder
CAUTION
•
PROFESSIONNAL INSTALLATION IS HIGHLY RECOMMENDED.
•
THIS STOVE USES A PRESSURIZED VENTING SYSTEM. ALL VENT CONNECTOR JOINTS MUST BE
SEALED AND FASTENED. YOU MAY USE RTV SILICONE (ROOM TEMPERATURE VULCANISATION),
METALLIC TAPE, AND A MINIMUM OF THREE SELF-TAPING SCREWS AT ALL JOINT
CONNECTIONS TO ENSURE A TIGHT SEAL
.
CONSULT THE PELLET VENT MANUFACTURER’S
INSTRUCTION TO ENSURE PROPER INSTALLATION, CONSISTENT PERFORMANCE, AND TO
AVOID SMOKE AND ASH SPILLAGE.
•
THE CHIMNEY CONNECTOR SHALL NOT PASS THROUGH AN ATTIC OR ROOF SPACE, CLOSET OR
SIMILAR CONCEALED SPACE OR FLOORS OR CEILING.
•
INSTALL VENTING SYSTEM AT CLEARANCES SPECIFIED BY THE VENT MANUFACTURER.
•
THE USE OF A SPARK ARRESTER AT THE END OF THE TERMINATION IS MANDATORY. IT IS
IMPORTANT THAT THE SPARK ARRESTER BE CLEAR OF ANY DEBRIS AT ALL TIME.
Содержание Cambridge EP00075
Страница 64: ...64 Cambridge Pellet Stove Installation and Operation Manual 10 WIRING DIAGRAM ...
Страница 72: ...72 Cambridge Pellet Stove Installation and Operation Manual 15 EXPLODED VIEW AND REPLACEMENT PARTS ...
Страница 73: ...Cambridge Pellet Stove Installation and Operation Manual 73 ...
Страница 74: ...74 Cambridge Pellet Stove Installation and Operation Manual ...
Страница 75: ...Cambridge Pellet Stove Installation and Operation Manual 75 ...
Страница 76: ...76 Cambridge Pellet Stove Installation and Operation Manual ...
Страница 77: ...Cambridge Pellet Stove Installation and Operation Manual 77 ...
Страница 78: ...78 Cambridge Pellet Stove Installation and Operation Manual ...
Страница 79: ...Cambridge Pellet Stove Installation and Operation Manual 79 ...