Cambridge Pellet Stove Installation and Operation Manual
65
11
ACCESS TO FUSES
WARNING: UNPLUG THE STOVE BEFORE CHANGING THE FUSES.
All fuses are located inside the stove on the main electronic board. The main board is located on the
right hand side of your stove. Unplug your stove, remove the right hand side decorative panel. Next,
remove the two screws holding the panel and rotate the panel.
LETTER
FUSE FUNCTION
AMPERAGE
A
MAIN BOARD FUSE
7.5A
B
CONVECTION BLOWER
5A
C
COMBUSTION BLOWER
3A
D
EXHAUST BLOWER
3A
E
TOP AUGER #1
3A
F
BOTTOM AUGER #2
3A
G
IGNITOR
5A