AQUAPURA SPLIT
8. RESOLUTION OF PROBLEMS
PROBLEM
POSSIBLE CAUSES
HOW TO PROCEED
Failure in
electronic
board
Power supply failure
Check the power supply.
Check the corresponding circuit breaker.
Cable damaged or disconnected
Check the integrity of the electronic board’s
electric circuit.
Low water tem-
perature
Equipment OFF
Press ON/OFF.
Cable damaged or disconnected
Check the connection of equipment to the plug
Check that the corresponding circuit-breaker is
connected.
Check the integrity of the cables.
Error in the operation of components.
Check for the presence of errors on the dash
-
board and refer to error chart.
Use of large amount of hot water
Activate the electrical heater support
Low temperature programmed as the
set-point
Adjust the temperature of the set-point
Return of hot water into the cold water
circuit (safety device incorrectly installed
or damaged)
Shut off the cold water supply valve to switch
off the safety device. Open a hot water tap.
Wait 10 minutes and if you get hot water, re
-
place the faulty plumbing and/or proceed with
the correct positioning of the safety device
Clean the filter of the safety device.
Water is too hot
and/or there is
steam
Problem with the probe
(T5L)
Check error display on electronic board
Problem with the safety thermostat
Check correct running of safety thermostat
.
Restart the controller (unplug the unit and
switch it back on).
Reduced heat
pump behaviour
and overextend-
ed resistance.
Outside air temperature is over the
equipment’s operating limits.
The equipments functionality depends on
weather conditions.
Low hot water
flow rate
Hydraulic circuit blocked
Check the condition of the hydraulic circuit
Water discharge
on the safety
group
Absence or incorrect sizing of expansion
vessel (if leak is not continuous)
Installation and/or correct dimensioning of ex-
pansion vessel
High mains pressure (if leak is continu
-
ous)
Check the reducing pressure valve (if installed)
Install a reducing pressure valve (if not in-
stalled)
Outside unit is
making a loud
noise.
Obstruction of unit components.
Clean the components that make up the out
-
side unit.
Vibration of some piece.
Make sure that all the components of the unit
are in good condition, properly accommodat
-
ed and free of vibrations.
Fan don’t
work
Dirty fan
Carry out a fan cleaning
Damage fan
Check fan status
Electric heater
not working
Safety thermostat ON
Check the condition of the thermostat
Defective electric heater
Check the electric heater
Others
---
Contact the service center
English
Technical Manual
Содержание AQUAPURA SPLIT 160i
Страница 2: ......
Страница 4: ...4 AQUAPURA SPLIT Manual T cnico Portugu s...
Страница 23: ...23 AQUAPURA SPLIT Manual T cnico Portugu s Esquema El trico unidade exterior...
Страница 36: ...36 AQUAPURA SPLIT English Technical Manual...
Страница 55: ...55 AQUAPURA SPLIT English Technical Manual Electric diagram outside unit...
Страница 68: ...68 AQUAPURA SPLIT Espa ol...
Страница 87: ...87 AQUAPURA SPLIT Espa ol Manual T cnico Esquema el ctrico unidad exterior...
Страница 99: ...99 AQUAPURA SPLIT Notas Notes Notas...
Страница 100: ...100 AQUAPURA SPLIT Notas Notes Notas...
Страница 101: ...101 AQUAPURA SPLIT Notas Notes Notas...
Страница 102: ...102 AQUAPURA SPLIT Notas Notes Notas...
Страница 103: ...103 AQUAPURA SPLIT Notas Notes Notas...
Страница 104: ...104 AQUAPURA SPLIT Notas Notes Notas...
Страница 105: ...105 AQUAPURA SPLIT Notas Notes Notas...
Страница 106: ...106 AQUAPURA SPLIT Notas Notes Notas...
Страница 107: ......