62
AQUAPURA SPLIT
Code
Description
Problem / Cause
Corrective action
P1
High pressure error – Active
high pressure switch.
Check that the temperature
sensor T5L is inside its case.
Check positioning of the T5L
sensor.
P2
Compressor overuse error.
Heater cylinder without water.
Check if the heater cylinder
is running out of water or if
there is a water leak.
Valves closed on the outside
unit.
Check that the valves are
open.
Folded cold circuit pipe.
Check piping.
Excessive coolant.
Check the amount of coolant.
Check that the temperature
sensor T5L is inside its case.
Check positioning of the T5L
sensor.
Not enough coolant.
Check the amount of coolant.
P4
Compressor discharge tem
-
perature is too high.
Heater cylinder without water.
Check if the heater cylinder
is running out of water or if
there is a water leak.
Valves closed on the outside
unit.
Check that the valves are
open.
Folded cold circuit pipe.
Check piping.
Excessive coolant.
Check the amount of coolant.
Check that the temperature
sensor T5L is inside its case.
Check positioning of the T5L
sensor.
Not enough coolant.
Check the amount of coolant.
bA
Outside air temperature is
over the equipment’s operat
-
ing limits.
Outside air temperature is over
the equipment’s operating lim
-
its.
****
HC
Electrical resistance con
-
sumption error (backup)
Resistance consumption is too
low.
Check resistance.
Resistance consumption is too
high.
EF
Main controller error (power
board).
Damaged driver.
Replace driver.
db
Protection against frost in
progress.
Water heater cylinder installed
in a place exposed to frost.
Install heater cylinder in an ap
-
propriate location.
4 way valve blocked or dam
-
aged.
Check 4 way valve.
English
Technical Manual
Содержание AQUAPURA SPLIT 160i
Страница 2: ......
Страница 4: ...4 AQUAPURA SPLIT Manual T cnico Portugu s...
Страница 23: ...23 AQUAPURA SPLIT Manual T cnico Portugu s Esquema El trico unidade exterior...
Страница 36: ...36 AQUAPURA SPLIT English Technical Manual...
Страница 55: ...55 AQUAPURA SPLIT English Technical Manual Electric diagram outside unit...
Страница 68: ...68 AQUAPURA SPLIT Espa ol...
Страница 87: ...87 AQUAPURA SPLIT Espa ol Manual T cnico Esquema el ctrico unidad exterior...
Страница 99: ...99 AQUAPURA SPLIT Notas Notes Notas...
Страница 100: ...100 AQUAPURA SPLIT Notas Notes Notas...
Страница 101: ...101 AQUAPURA SPLIT Notas Notes Notas...
Страница 102: ...102 AQUAPURA SPLIT Notas Notes Notas...
Страница 103: ...103 AQUAPURA SPLIT Notas Notes Notas...
Страница 104: ...104 AQUAPURA SPLIT Notas Notes Notas...
Страница 105: ...105 AQUAPURA SPLIT Notas Notes Notas...
Страница 106: ...106 AQUAPURA SPLIT Notas Notes Notas...
Страница 107: ......