RID16
Operation via FOUNDATION™ Fieldbus
Hauser
53
DISP_VALUE_1[...8]_LISTENER_VALUE:
The currently choosen value of a publishing device. The address of this device
is selected in "Listener device" and the value in "Listener value select" starting
with 1.
DISP_VALUE_1[...8]_SOURCE_ANALOG:
Select an analog type input of a function block to show its value on the
display.
Available parameters are:
• Off
• ISEL1.IN_1
• ISEL1.IN_2
• ISEL1.IN_3
• ISEL1.IN_4
• ISEL1.OUT
• ISEL2.IN_1
• ISEL2.IN_2
• ISEL2.IN_3
• ISEL2.IN_4
• ISEL2.OUT
• PID.IN
• PID.OUT
• PID.SP
• INTG.IN_1
• INTG.IN_2
• INTG.OUT
• AR.IN
• AR.IN_1
• AR.IN_2
• AR.IN_3
• AR.OUT
DISP_VALUE_1[...8]_SOURCE_DIGITAL:
Select an digital type input of a function block to show its value on the
display. Available parameters are:
• Off
• ISEL1.DISABLE_1
• ISEL1.DISABLE_2
• ISEL1.DISABLE_3
• ISEL1.DISABLE_4
• ISEL2.DISABLE_1
• ISEL2.DISABLE_2
• ISEL2.DISABLE_3
• ISEL2.DISABLE_4
DISP_VALUE_1[...8]_DESC:
Enter a free text with maximum 16 characters. This text is displayed below
the value. It will scroll if the text is longer than 5 characters.
DISP_VALUE_1[...8]_FORMAT:
Number of places after decimal point for the display.
Available parameters are:
• Auto (the device automatically sets the position of the decimal point to fill
all 5 digits of the display)
• XXXXX
• XXXX.X
• XXX.XX
• XX.XXX
• X.XXXX
DISP_VALUE_1[...8]_BGMIN:
Enter the minimum (0%) value for bargraph presentation.
Transducer Block “DISPLAY” (E+H parameters)