Electrical connection
Proline t-mass T 150
26
Hauser
7.1.3
Terminal assignment
Transmitter
Connection version 4-20 mA HART, pulse/frequency/switch output, status input
5
1
2
3
1
2
23
22
24
25
26
27
4
A0017178
1
Supply voltage
2
Status input
3
Signal transmission: pulse/frequency/switch output
4
Signal transmission: 4-20 mA HART
5
Ground terminal for cable shield
Supply voltage
Order code for
"Power supply"
Terminal numbers
1 (L+)
2 (L-)
Option
D
DC 18 to 30 V
1)
Securely tighten the screws of the terminal. Recommended torque: 0.5 Nm.
Signal transmission
Order code
for
"Output,
input"
Terminal numbers
Output 1
Output 2
Input
26 (+)
27 (-)
24 (+)
25 (-)
22 (+)
23 (-)
Option
A
4-20 mA HART (active)
-
-
Option
B
4-20 mA HART (active)
Pulse/frequency/switch output
(passive)
-