Proline t-mass B 150
Installation
Hauser
19
Has the correct orientation for the sensor been selected (
®
ä
11)?
• According to sensor type
• According to medium properties
• According to medium temperature
• According to process pressure
q
Does the arrow on the sensor match the direction of flow of the medium through the piping
(
®
ä
11)?
q
Have sufficient inlet and outlet runs been provided upstream and downstream of the measuring point?
q
Correctly aligned in the direction of flow?
q
Correct sensor immersion depth?
q
Is the device adequately protected from precipitation and direct sunlight?
q
Is the device protected against overheating?
q
Is the device protected against excessive vibrations?
q
Check gas property (e.g. purity, dryness, cleanness).
q
Are the measuring point identification and labeling correct (visual inspection)?
q
Содержание Proline t-mass B 150