Proline t-mass B 150
Diagnostic information and remedial measures
Hauser
37
E
+
–
ON
OFF
1
2
1
2
A0017255
1. Unscrew the electronics compartment cover.
2. Pull out the display module with a gentle rotational movement.
3. To make it easier to access the lock switch, attach the display module to the edge of the
electronics compartment.
4. Setting the lock switch (WP) on the electronics module to the ON position enables the
hardware write protection.
Ã
The symbol appears in the header of the measured value display and in the
navigation view in front of the parameters.
5. Feed the ribbon cable into the gap between the housing and electronics module and plug
the display module into the electronics compartment in the desired direction until it
engages.
6. Screw down the electronics compartment cover
10
Diagnostic information and remedial measures
Faults detected by the self-monitoring system of the measuring device are displayed as a
diagnostic message in alternation with the operational display. The message on the remedial
measures can be called up from the diagnostic message, and contains important information on
the fault.