Proline t-mass B 150
Installation
Hauser
17
1. Ensure that the direction of the arrow on the sensor matches the flow direction of the
medium.
2.
230
220
210
200
190
180
9
8
7
1½
30 mm
A0017331
Ensure the insertion depth and alignment are correct. Thread adapter nut: when mounting
for the first time, tighten it finge 1½ turns. For all other mounting routines, tighten
it fingertight and 1 additional turn
3. Install the measuring device or turn the transmitter housing so that the cable entries do
not point upwards.
Ã
A0013964
6.2.4
Turning the transmitter housing
To provide easier access to the connection compartment or display module, the transmitter
housing can be turned clockwise or counterclockwise to 4 indexed positions by a maximum of
2 x 90
°
:
Содержание Proline t-mass B 150