Proline Prowirl R 200
Diagnostic information
Hauser
53
+
E
–
3 mm
XXXXXXXXXXXXX
WP
CDI
SIM
ON
OFF
A0013768
1. Loosen the securing clamp.
2. Unscrew the electronics compartment cover.
3. Pull out the display module with a gentle rotational movement. To make it easier
to access the lock switch, attach the display module to the edge of the electronics
compartment.
Display module is attached to the edge of the electronics compartment.
4. Setting the write protection switch (WP) on the main electronics module to the
ON position enables the hardware write protection.
The
Hardware locked
option is displayed in the
Locking status
parameter.
In addition, on the local display the -symbol appears in front of the
parameters in the header of the operational display and in the navigation
view.
5. Feed the cable into the gap between the housing and main electronics module
and plug the display module into the electronics compartment in the desired
direction until it engages.
6. Reverse the removal procedure to reassemble the transmitter.
11
Diagnostic information
Faults detected by the self-monitoring system of the measuring device are displayed as
a diagnostic message in alternation with the operational display. The message on