Electrical connection
Proline Prowirl R 200
26
Hauser
7.1.3
Terminal assignment
Transmitter
Connection versions
–
4
+
1
–
2
+
3
1
2
4
–
6
+
5
3
A0020738
+
1
–
2
–
4
+
3
–
6
+
5
3
1
2
4
A0020739
Maximum number of terminals
Terminals 1 to 6:
Without integrated overvoltage protection
Maximum number of terminals for order code for
"Accessory mounted", option NA "Overvoltage
protection"
•
Terminals 1 to 4:
With integrated overvoltage protection
•
Terminals 5 to 6:
Without integrated overvoltage protection
1
2
3
4
Output 1 (passive): supply voltage and signal transmission
Output 2 (passive): supply voltage and signal transmission
Input (passive): supply voltage and signal transmission
Ground terminal for cable shield
Order code for "Output"
Terminal numbers
Output 1
Output 2
Input
1 (+)
2 (-)
3 (+)
4 (-)
5 (+)
6 (-)
Option
A
4-20 mA HART (passive)
-
-
Option
B
4-20 mA HART (passive)
Pulse/frequency/switch
output (passive)
-
Option
C
4-20 mA HART (passive)
4-20 mA (passive)
-
Option
D
4-20 mA HART (passive)
Pulse/frequency/switch
output (passive)
4-20 mA current input
(passive)
Option
G
PROFIBUS PA
Pulse/frequency/switch
output (passive)
-
1)
Output 1 must always be used; output 2 is optional.
2)
PROFIBUS PA with integrated reverse polarity protection.
Remote version
In the case of the remote version, the sensor and transmitter are mounted separately
from one another and connected by a connecting cable. The sensor is connected via the