Basic safety instructions
Proline Prowirl R 200
6
Hauser
‣
If the measuring device is not operated at atmospheric temperature, compliance
with the relevant basic conditions specified in the device documentation provided
(on the CD-ROM) is absolutely essential.
Incorrect use
Non-designated use can compromise safety. The manufacturer is not liable for damage
caused by improper or non-designated use.
!
WARNING
Danger of breakage of the sensor due to corrosive or abrasive fluids!
‣
Verify the compatibility of the process fluid with the sensor material.
‣
Ensure the resistance of all fluid-wetted materials in the process.
‣
Observe the specified pressure and temperature range.
Verification for borderline cases:
‣
For special fluids and fluids for cleaning, Hauser is glad to provide
assistance in verifying the corrosion resistance of fluid-wetted materials, but does
not accept any warranty or liability as minute changes in the temperature,
concentration or level of contamination in the process can alter the corrosion
resistance properties.
Residual risks
Possible burn hazard due to fluid temperatures!
‣
For elevated fluid temperature, ensure protection against contact to prevent burns.
2.3
Workplace safety
For work on and with the device:
‣
Wear the required personal protective equipment according to federal/national
regulations.
For welding work on the piping:
‣
Do not ground the welding unit via the measuring device.
2.4
Operational safety
Risk of injury.
‣
Operate the device in proper technical condition and fail-safe condition only.
‣
The operator is responsible for interference-free operation of the device.
2.5
Product safety
This measuring device is designed in accordance with good engineering practice to
meet state-of-the-art safety requirements, has been tested, and left the factory in a
condition in which it is safe to operate.
It meets general safety standards and legal requirements. It also complies with the EC
directives listed in the device-specific EC Declaration of Conformity. Hauser
confirms this by affixing the CE mark to the device.