background image

Products

Solutions

Services

TI00076D/06/EN/13.15

71231024

Technical Information

Proline Promass 80S, 83S

Coriolis flowmeter

Easy-to-clean flowmeter with self-drainable single-tube system & extended 

transmitter functionality

Application

• Measuring principle operates independently of physical fluid 

properties such as viscosity or density

• Dedicated for applications requiring optimal cleanability 

under hygienic conditions

Device properties

• Large range of hygienic process connections

• 3A and EHEDG conform

• Fast recovery from CIP/SIP

• Device in compact or remote version
Promass 83

• 4-line backlit display with touch control

• HART, PROFIBUS PA/DP, Modbus RS485, FF, EtherNet/IP 

Your benefits

• Reduced installation costs – fully self-drainable tube design 

enables compact horizontal mounting

• Fewer process measuring points – multivariable 

measurement (flow, density, temperature)

• Space-saving installation – no in/outlet run needs
Promass 83

• Quality – software for filling & dosing, density & 

concentration, advanced diagnostics

• Flexible data transfer options – numerous communication 

types

• Automatic recovery of data for servicing

Содержание Proline Promass 80S

Страница 1: ...of hygienic process connections 3A and EHEDG conform Fast recovery from CIP SIP Device in compact or remote version Promass 83 4 line backlit display with touch control HART PROFIBUS PA DP Modbus RS48...

Страница 2: ...Special installation instructions 18 Environment 19 Ambient temperature range 19 Storage temperature 19 Degree of protection 19 Shock resistance 19 Vibration resistance 19 Electromagnetic compatibilit...

Страница 3: ...low Electrodynamic sensors register the tube oscillations at the inlet and outlet The system balance required for proper measurement is created by exciting an eccentrically arranged swinging mass to a...

Страница 4: ...play Operation with push buttons Promass 83 a0003672 Four line liquid crystal display Operation with Touch control Application specific Quick Setup Mass flow volume flow density and temperature measur...

Страница 5: ...are registered correctly Input signal Status input auxiliary input U 3 to 30 V DC Ri 5 k galvanically isolated Configurable for totalizer reset positive zero return error message reset zero point adj...

Страница 6: ...re Totalizer Input data Positive zero return ON OFF Zero point adjustment Measuring mode Totalizer control Bus address can be configured via miniature switches or via the local display optional Promas...

Страница 7: ...evice type slave Address range 1 to 247 Supported function codes 03 04 06 08 16 23 Broadcast supported with the function codes 06 16 23 Physical interface RS485 in accordance with EIA TIA 485 standard...

Страница 8: ...Promass 80 Open collector Max 30 V DC 250 mA Galvanically isolated Configurable for error messages Empty Pipe Detection EPD flow direction limit values Relay output Promass 83 Max 30 V 0 5 A AC 60 V...

Страница 9: ...ssive Current output 1 Ex i passive HART Flexible communication boards C Relay output 2 Relay output 1 Frequency output Current output HART D Status input Relay output Frequency output Current output...

Страница 10: ...Promass 80 Lasting min 1 power cycle EEPROM saves measuring system data if the power supply fails HistoROM S DAT exchangeable data storage chip with sensor specific data nominal diameter serial numbe...

Страница 11: ...everse polarity protection Terminal No 27 DP A PA FF Modbus RS485 A PA FF with reverse polarity protection e Ground terminal for signal cable shield fieldbus cable RS485 line f Service adapter for con...

Страница 12: ...rsion Cable entry M20 1 5 8 to 12 mm 0 31 to 0 47 Thread for cable entries NPT G Cable specification Remote version 6 0 38 mm PVC cable with common shield and individually shielded cores Conductor res...

Страница 13: ...entire measuring range of the sensor 19 Special density calibration 0 002 g cm3 optional valid range 5 to 80 C 41 to 176 F and 0 to 2 0 g cm Temperature 0 5 C 0 005 T C 1 F 0 003 T 32 F Zero point sta...

Страница 14: ...ids 0 00025 g cm3 Temperature 0 25 C 0 0025 T C 0 45 F 0 0015 T 32 F Response time The response time depends on the configuration damping Response time in the event of erratic changes in the measured...

Страница 15: ...eatability depending on flowrate Example for maximum measured error A0016709 E Error Maximum measured error as o r example Promass 83S Q Flow rate as DN Promass S mm in o r bar 8 0 002 15 0 006 25 1 0...

Страница 16: ...ting location Notwithstanding the above the installation proposal below permits installation in an open vertical pipeline Pipe restrictions or the use of an orifice with a smaller cross section than t...

Страница 17: ...the sensor has to be matched to the fluid properties a0004581 Horizontal installation for sensors with a bent measuring tube 1 Not suitable for fluids with entrained solids Risk of solids accumulating...

Страница 18: ...n instructions It is not necessary to support the sensor under any circumstances for operational performance If the requirement exists to support the sensor the following recommendation should be foll...

Страница 19: ...bility EMC As per IEC EN 61326 and NAMUR recommendation NE 21 Process Fluid temperature range Sensor 50 to 150 C 58 to 302 F Medium density 0 to 5000 kg m 0 to 312 lb ft Fluid pressure range nominal p...

Страница 20: ...be filled immediately with a dry inert gas Use only low gauge pressure to purge Maximum pressure 5 bar 72 5 psi If a device equipped with purge connections is connected to the purge system the maximu...

Страница 21: ...eals and counterparts as these components can limit the pressure and temperature range DIN 11864 1A thread DIN 11864 3A clamp Connection material 1 4435 316L A0020969 EN 10K 40K 20K 300 F 350 250 200...

Страница 22: ...O 2853 thread Connection material 1 4435 316L A0020919 EN Tri Clamp The Clamp connections are suited up to a maximum pressure of 16 bar 232 psi Please observe the operating limits of the clamp and sea...

Страница 23: ...that occur naturally in many liquids do not outgas Such effects can be prevented when system pressure is sufficiently high Therefore the following locations should be preferred for installation Downst...

Страница 24: ...B2220 flange 10K JIS B2220 flange 20K JIS B2220 flange 40K 32 Tri Clamp DIN 11866 line C Tri Clamp 1 DIN 11866 line C Tri Clamp DIN 11866 line C Tri Clamp DIN 11866 line C 33 DIN 11851 thread DIN 118...

Страница 25: ...477 132 1 1 50 227 207 187 168 160 315 241 556 167 1 1 without local display 1 dependent on respective process connection All dimensions in mm DN A A B C D E F G K L di 9 08 8 28 7 48 6 72 6 4 11 02 4...

Страница 26: ...8 54 8 11 7 32 7 01 11 02 4 95 15 98 3 62 1 1 1 9 45 8 54 8 11 7 32 7 01 11 02 5 46 16 49 3 62 1 1 1 9 45 8 54 8 11 7 32 7 01 11 97 7 51 19 48 5 20 1 1 2 9 45 8 54 8 11 7 32 7 01 12 40 10 19 22 59 6 5...

Страница 27: ...ll dimensions in mm A A B B C D E F G H J K L M 10 4 9 53 9 45 8 54 8 11 7 32 7 01 M8 3 94 5 12 3 94 5 67 6 69 13 7 Blind version without local display All dimensions in in A B C Nicht unter S pannung...

Страница 28: ...45 50 81 53 L M N O P Q R S T 1 95 53 102 81 5 11 5 192 8 M5 20 2 6 5 1 Securing screw for wall mounting M6 screw head max 10 5 mm All dimensions in mm A B C D E F G H J K 8 46 9 84 3 56 6 27 5 31 3 5...

Страница 29: ...ensions in SI units Dimensions in US units DN A B C 8 118 5 137 5 138 15 118 5 137 5 138 25 118 5 137 5 138 40 118 5 137 5 152 50 118 5 137 5 167 All dimensions in mm DN A B C 4 67 5 41 5 43 4 67 5 41...

Страница 30: ...de for Process connection option D2Z DN G L N S LK U di 8 1 95 0 336 4 14 17 0 65 0 17 30 8 31 15 95 0 440 4 14 20 0 65 0 17 30 12 00 25 115 0 580 4 14 19 0 85 0 28 50 17 60 40 150 0 794 4 18 21 0 110...

Страница 31: ...12 00 25 108 0 580 4 15 7 17 6 79 2 26 70 17 60 40 127 0 794 4 15 7 18 6 98 6 40 90 26 00 50 152 4 1071 4 19 1 25 1 120 7 52 60 40 50 1 DN 8 with DN 15 flange as standard All dimensions in mm Flange...

Страница 32: ...nnection option NDZ DN G L N S LK U di 8 1 95 336 4 15 16 0 70 0 15 00 8 31 15 95 440 4 15 16 0 70 0 15 00 12 00 25 125 580 4 19 17 5 90 0 25 00 17 60 40 140 794 4 19 20 0 105 0 40 00 26 00 50 155 107...

Страница 33: ...it Order code for Process connection option FTM DN Clamp G L U di 8 25 0 362 9 40 8 31 15 25 0 466 15 75 12 00 25 1 50 4 606 22 10 17 60 40 1 50 4 818 34 80 26 00 50 2 63 9 1096 47 50 40 50 All dimens...

Страница 34: ...G U 1 5 2 0 L 0 06 0 08 DIN 11851 thread DIN 11866 line A 1 4435 316L Surface roughness Ra 0 8 m 150 grit Order code for Process connection option FMD DN G L U di 8 Rd 34 362 16 00 8 31 15 Rd 34 466...

Страница 35: ...1 5 2 0 L 0 06 0 08 DN 11864 1A thread DIN 11866 line A 1 4435 316L Surface roughness Ra 0 8 m 150 grit Order code for Process connection option FLH DN G L U di 8 Rd 34 362 16 00 8 31 15 Rd 34 466 16...

Страница 36: ...cordingly a larger groove Engineering unit mm in E di G S LK U N 1 5 2 0 L 0 06 0 08 A A DIN 11864 2A flange DIN 11866 line A flange with notch 1 4435 316L Surface roughness Ra 0 8 m 150 grit Order co...

Страница 37: ...E di 1 5 2 0 L G U 0 06 0 08 DIN 11864 3A clamp DIN 11866 line A with notch 1 4435 316L Surface roughness Ra 0 8 m 150 grit Order code for Process connection option FWA DN G L U di 8 34 0 370 16 00 8...

Страница 38: ...E di G U 1 5 2 0 L 0 06 0 08 DIN 32676 clamp DIN 11866 line A 1 4435 316L Surface roughness Ra 0 8 m 150 grit Order code for Process connection option FDW DN G L U di 8 34 0 362 16 00 8 31 15 34 0 466...

Страница 39: ...E di G U 1 5 2 0 L 0 06 0 08 ISO 2852 clamp ISO 2037 1 4435 316L Surface roughness Ra 0 8 m 150 grit Order code for Process connection option FEA DN G L U di 8 50 5 362 22 60 8 31 15 50 5 466 22 60 12...

Страница 40: ...di G U 1 5 2 0 L 0 06 0 08 ISO 2853 thread ISO 2037 1 4435 316L Surface roughness Ra 0 8 m 150 grit Order code for Process connection option FJG DN G L U di 8 37 13 370 22 60 8 31 15 37 13 474 22 60 1...

Страница 41: ...2 0 L 0 06 0 08 SMS 1145 thread 1 4435 316L Surface roughness Ra 0 8 m 150 grit Order code for Process connection option FSD DN G L U di 8 Rd 40 1 6 362 22 50 8 31 15 Rd 40 1 6 466 22 50 12 00 25 Rd...

Страница 42: ...50 17 32 4 0 62 0 67 2 38 0 62 0 47 1 4 25 22 83 4 0 62 0 69 3 12 1 05 0 69 1 5 00 32 26 4 0 62 0 73 3 88 1 61 1 02 2 6 00 42 17 4 0 75 0 99 4 75 2 07 1 59 1 DN with DN flange as standard All dimensio...

Страница 43: ...ption FTM DN Clamp G L U di 0 98 14 25 0 37 0 33 0 98 18 35 0 62 0 47 1 1 1 98 23 86 0 87 0 69 1 1 1 98 32 20 1 37 1 02 2 2 2 52 43 15 1 87 1 59 All dimensions in in Tri Clamp 1 DIN 11866 line C 1 443...

Страница 44: ...connection option FUG DN Clamp G L U di 0 98 18 35 0 37 0 47 All dimensions in in E di G U 1 5 2 0 L 0 06 0 08 SMS 1145 thread 1 4435 316L Surface roughness Ra 32 in 150 grit Order code for Process co...

Страница 45: ...82 3 23 110 4 34 15 NPT 25 0 98 82 3 23 204 8 04 25 1 NPT 25 0 98 82 3 23 348 13 54 40 1 NPT 45 1 77 102 4 02 526 20 70 50 2 NPT 58 2 28 119 5 4 70 763 30 04 H A G L DN mm 8 15 25 40 50 Compact versi...

Страница 46: ...ss steel 1 4301 304 Process connections Flanges according to EN 1092 1 DIN 2501 Flanges according to ASME B16 5 JIS B2220 flange stainless steel 1 4404 316 316L All other process connections stainless...

Страница 47: ...tries You can change the language group via the operating program FieldCare Remote operation Promass 80 Remote operation via HART PROFIBUS PA Promass 83 Remote operation via HART PROFIBUS PA DP FOUNDA...

Страница 48: ...oundation The device thus meets all the requirements of the following specifications Certified in accordance with HART Revisions 5 and 7 device certification number available on request The measuring...

Страница 49: ...easures for Electrical Equipment for Measurement Control Regulation and Laboratory Procedures EN 61508 Functional Safety of Electrical Electronic Programmable Electronic Safety related Systems IEC EN...

Страница 50: ...ed individually Advanced diagnostics Batching functions Concentration measurement Mounting set for transmitter Mounting set for wall mount housing remote version Suitable for Wall mounting Pipe mounti...

Страница 51: ...ck Tester simulator for testing flowmeters in the field When used in conjunction with the FieldCare software package test results can be imported into a database printed and used for official certific...

Страница 52: ...ementary documentation on Ex ratings ATEX FM CSA IECEx NEPSI Functional safety manual Promass 80 83 SD00077D Registered trademarks KALREZ and VITON Registered trademarks of E I Du Pont de Nemours Co W...

Страница 53: ...Proline Promass 80S 83S Endress Hauser 53...

Страница 54: ...www addresses endress com...