5.3.3
Factory settings (reset)
"
Caution!
A reset sets the device back to the factory settings. This can lead to an impairment of the
measurement. Generally, you should perform a basic setup again following a reset.
A reset is only necessary:
• If the device no longer works
• If the device must be moved from one measuring point to another
• If the device is being removed/put into storage/installed
User input ("reset" (0A3)):
• 33333 = customer parameters
33333 = reset customer parameters
This reset is recommended whenever a device with an unknown 'history' is to be used in an
application:
• The Levelflex is reset to the default values.
•
A customer-specific tank map is not deleted.
• The mapping can be deleted in the "
cust. tank map
"
(055)
function of the "
extended
calibr
"
(05)
function group.
• A linearization is switched to "
linear
" but the table values are retained. The table can be
reactivated in the "
linearization
"
(04)
function group.
List of functions that are affected by a reset:
• A complete “
basic setup
"
(00)
must be activated.
⇒
E HAUSER
E
+
–
• Tank properties (002)
• Medium property (003)
• Process proper. (004)
• Empty calibr. (005)
• Full calibr. (006)
• Output on alarm (010)
• Outp. echo loss (012)
• Ramp %span/min (013)
• Delay time (014)
• Safety distance (015)
• In safety dist. (016)
• Overfill protection (018)
• End of probe (030)
• Level/ullage (040)
• Linearization (041)
• Customer unit (042)
• Max. scale (046)
• Diameter vessel (047)
• Check distance (051)
• Range of mapping (052)
• Start mapping (053)
• Offset (057)
• Output damping (058)
• Language (092)
• Back to home (093)
• Format display (094)
• No of decimals (095)
• Sep. character (096)
• Unlock parameter (0A4)
• application par (0A8)
• tag no (0C0)
Содержание Levelflex M FMP43
Страница 4: ...Brief overview Levelflex M FMP43 with PROFIBUS PA 4 Endress Hauser...
Страница 104: ...Appendix Levelflex M FMP43 with PROFIBUS PA 104 Endress Hauser...
Страница 106: ...Levelflex M FMP43 with PROFIBUS PA Index 106 Endress Hauser...
Страница 108: ...www endress com worldwide BA358F 00 en 07 07 No 71041163 CCS FM SGML 6 0 ProMoDo 71041163...