background image

24032-2-1008

Page 36

CAUTION:

 Label all wires prior to disconnection when servicing 

controls.  Wiring  errors  can  cause  improper  and  dangerous 

operation. Verify proper operation after servicing. 

Cleaning

The blower wheel will collect lint and could require cleaning once 

a year. If the air output decreases or the noise level increases, it 

indicates a dirty wheel. 

Blower Motor

The blower motor does not have oiling holes. Do not attempt to 

oil blower motor.

Wiring

The appliance, when installed, must be electrically grounded in 

accordance with local codes or, in the absence of local codes, with 

the 

National Electrical Code, ANSI/NFPA 70 or Canadian Electrical 

Code, CSA C22.1

, if an external electrical source is utilized. 

This 

appliance is equipped with a three-prong [grounding] plug for 

your protection against shock hazard and should be plugged 

directly into a properly grounded three-prong receptacle.  Do 

not cut or remove the grounding prong from this plug. 

 For an 

ungrounded receptacle, an adapter, which has two prongs and a 

wire for grounding, can be purchased, plugged into the ungrounded 

receptacle and its wire connected to the receptacle mounting screws.  

With this wire completing the ground, the appliance cord plug can 

be plugged into the adapter and be electrically grounded. 

WARNING:

Unplugging  of  blower  accessory  will  not  stop  the  heater 

from cycling. To shut heater off: Turn temperature dial or 

thermostat to lowest setting. Turn knob on gas control to 

"OFF," depressing slightly. Do not force.

OPTIONAL BLOWER INSTALLATION INSTRUCTIONS

Figure 41

1

2

3

5

6

7

8

9

10

11

4

PARTS LIST

INDEX 

NUMBER

PART 

NUMBER

DESCRIPTION

1

R-1454

BRASS BUSHING

2

R-1499

RUBBER GROMMET

3

24231

BLOWER HOUSING

4

R-1410

STRAIN RELIEF BUSHING

5

R-9927

BLOWER ASSEMBLY

6

24225

BLOWER COVER

7

R-6159

CORD SET

8

R-9699

WIRE HARNESS

9

R-2503

FAN CONTROL

10

24222

FAN CONTROL BRACKET

11

R-2805

AUTO OFF/ON SWITCH

Содержание DVP30CA30B-N1

Страница 1: ...30CA30 B F M S W N 1 DVP30CA30 B F M S W P 1 Do not store or use gasoline or other ammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to l...

Страница 2: ...tem Identi cation 16 Framing and Finishing 17 18 Horizontal Termination 18 Vertical Termination 19 20 Log Placement 21 Operating Guidelines 22 Lighting Instructions 23 Pilot Flame Characteristics 24 M...

Страница 3: ...ace is temperedglass Iftheglassiscrackedordamagedin any way it should be replaced only with a complete glass frame assembly from Empire See parts list on Page 30 for ordering DONOTusethis replaceifany...

Страница 4: ...heodorantinescapedgascanadsorborabsorbontoorintowalls masonry and other materials and fabrics in a room That will take some of the odorant out of the gas reducing its odor intensity LP Gas may stratif...

Страница 5: ...ply with NFPA 720 and be ANSI UL 2034 listed and IAS certi ed 3 SIGNAGE Ametalorplasticidenti cationplateshallbe permanently mounted to the exterior of the building at a minimum height of eight 8 feet...

Страница 6: ...in such work familiar with all precautions required and has complied with all the requirements of the authority having jurisdiction The installation must conform with local codes or in the absence of...

Страница 7: ...6DVA E90B DVKVP Direct Vent Kit for Vertical Run 2 46DVA 48B 46DVA DC 46DVA F6 46DVA SC 46DVA FS 46DVA VCH Accessories TMV Millivolt Wall Thermostat Reed Switch FRBC Battery Operated Remote Control FR...

Страница 8: ...This should consist of a vertical length of pipe tee connected into the gas line that is capped on the bottom in which condensation and foreign particles may collect When using copper or ex connector...

Страница 9: ...rs 45 angle to Wall 4 101 6 mm Floor 0 0 mm Installation on Rugs and Tile This appliance must be installed on a at solid continuous surface e g wood metal concrete This may be the oor or it may be rai...

Страница 10: ...te must be used above 10 feet Maximum horizontal run from appliance outlet 12 feet 3 66 m Maximum vertical rise and horizontal run is a combined total of 25 feet 7 62 m Maximum elbows 2 90 for the sec...

Страница 11: ...ide and bottom Cutting the Hole Figure 7 After the appliance has been positioned in its permanent location the hole through the exterior wall of the house can be cut This hole needs to be 10 high x 10...

Страница 12: ...2 Remove cast iron front and carefully set aside 3 Carefully remove glass door 4 Remove the log shelf by removing the 2 screws securing the log shelf to the wall 5 Loosen the upper 2 screws of both ai...

Страница 13: ...ack down locking the air shutter in place Be sure that the air shutter is the same distance from the burner ori ce on both sides of the air shutter for proper burner t up 10 Carefully replace the burn...

Страница 14: ...ng Routes and Components Important It is always best to locate the appliance in such a way that minimizes the number of offsets and horizontal vent length Figure 14 Since it is very important that the...

Страница 15: ...e of the regulator I Clearance to service regulator vent outlet 6 feet 1 83 m minimum J Clearance to non mechanical air supply inlet to building or the combustion air inlet to any other appliance 12 i...

Страница 16: ...hes The vent pipe is now locked together Continue adding components per the pre planned vent system con guration Be certain that each succeeding vent component is securely tted and locked into the pre...

Страница 17: ...usly cut Secure with nails or screws Continue the vent run through the restops See Figure 19 Figure 19 Vertical runs of this system which pass through ceilings require the use of ONE 1 ceiling restop...

Страница 18: ...provided Before attachment of the termination run a bead of silicone sealant rated above 250 F on its outside edge too so as to make a seal to that exterior wall NOTE Wood screws can and should be rep...

Страница 19: ...are as follows 1 Check areas of the venting system which are exposed to the elements for corrosion These will appear as rust spots or streaks and in extreme cases holes These components should immedi...

Страница 20: ...bustiblematerials includinginsulation to the vent system are maintained Vertical Through the Roof Applications Your Gas Fireplace has been approved for a Vertical installations up to 25 feet of vent r...

Страница 21: ...on the groove in the left front log 12 Place right twig onto right side pin on rear log with toe resting all the way to the right on the right front log 13 Align and place top of glass frame over lip...

Страница 22: ...to OFF Standing Pilot Operation 1 Follow the SAFETY and LIGHTING INSTRUCTIONS for standing pilot controls found in this manual and on labels found attached to the appliance CAUTION Duringtheinitialpur...

Страница 23: ...a pilot which must be lighted by hand When lighting the pilot follow these instructions exactly B BEFORELIGHTINGsmellallaroundtheappliancearea for gas Be sure to smell next to the oor because some ga...

Страница 24: ...mopilejustbelow the tip A slight yellow ame may occur where the pilot ame and main burner ame meet The incorrect pilot ame is not touching the thermocouple or thermopile This will cause the thermocoup...

Страница 25: ...epersonshouldcleandust lint and any light accumulation from the logs and the rebox area An extra soft brush should be used on the logs as they are extremely fragile a vacuum cleaner may be used on the...

Страница 26: ...en wires female push ons attach to the ON OFF REMOTE switch At the opposite end of the wire harness the black and green wires female push ons attach to the gas valve An additional green wire and the r...

Страница 27: ...24032 2 1008 Page 27 Wiring Diagram Figure 34 WIRING continued...

Страница 28: ...ass frame assembly on a non abrasive surface The exterior of the glass frame assembly should be facing the non abrasive surface 7 Insert a putty knife between glass and bottom corners on frame Careful...

Страница 29: ...ivolts minimum while holding thevalveknobdepressedtothepilotposition withthepilot lit and the ON OFF switch in the OFF position Replace the faulty thermopile if the reading is below the speci ed minim...

Страница 30: ...UE OUTLET GASKET 3 REQUIRED 5 24176 AIR DROP ASSEMBLY 6 R 9678 AIR DROP ASSEMBLY TRANSITION GASKET 7 24015 AIR DROP TRANSITION 8 R 9679 FIREBOX TRANSITION GASKET 9 17379 BLOW PLATE BRACKET 2 REQUIRED...

Страница 31: ...24032 2 1008 Page 31 PARTS VIEW 1 9 4 2 3 4 6 4 8 10 11 12 14 15 16 28 29 31 36 37 38 39 40 41 42 43 44 45 30 17 18 19 20 21 22 24 25 26 27 32 34 35 23 13 33 5 7 29 47 9 46...

Страница 32: ...IGHT 8 R 9694 CASTING DOOR LEFT 9 24042 FIREBOX SUPPORT BRACKET 2 REQUIRED 11 R 9549 CASTING LEG B 12 R 9548 CASTING LEG A PORCELAIN BLACK 1 R 9570 TOP INSERT RIGHT 2 R 9569 TOP INSERT LEFT 3 R 9568 C...

Страница 33: ...24032 2 1008 Page 33 1 2 8 3 4 5 6 7 9 9 10 10 10 10 12 11 11 12 CASTING PARTS VIEW...

Страница 34: ...o casting before fully tightening bolts as shown in Figure 37 9 Replace cast iron or stone inlay inserts into casting top Note Be sure to remove side shelf supports prior to removing cast iron top to...

Страница 35: ...lot 6 Route fan control wires through rectangular notch on wire channel left 7 Attach 1 4 push on terminal from blue wire on the fan control to the AUTO top tab on the switch OPTIONAL BLOWER INSTALLAT...

Страница 36: ...ly into a properly grounded three prong receptacle Do not cut or remove the grounding prong from this plug For an ungrounded receptacle an adapter which has two prongs and a wire for grounding can be...

Страница 37: ...nt Then determine the Part Number not the Index Number and the Description of each part from the following appropriate illustration and list Be sure to give all this information Stove Model Number Sto...

Страница 38: ...24032 2 1008 Page 38 SERVICE NOTES...

Страница 39: ...facing the front of the direct vent replace the minimum clearances to combustible construction material are the following Top of appliance ceiling 36 inches Heater Corners 45 angle to Wall 4 inches Re...

Страница 40: ...s Empire Comfort Systems Inc 918 Freeburg Ave Belleville IL 62220 If you have a general question about our products please e mail us at info empirecomfort com If you have a service or repair question...

Отзывы: