24032-2-1008
Page 23
1. STOP! Read the safety information above.
2. Set the thermostat to lowest setting.
3. Turn off all electric power to the appliance (if appli-
cable).
4. Lower valve cover.
5. Push in gas control knob slightly and turn clockwise
to "OFF."
6. Wait ten (10) minutes to clear out any gas. Then smell
for gas, including near the floor. If you smell gas, STOP!
Follow "B" in the safety
information above. If you
don't smell gas, go to the
next step.
7. Find pilot - The pilot is at-
tached to the main burner
behind the front log.
8. Turn knob on gas control counterclockwise
to
"PILOT."
9. Push in gas control knob all the way and hold in. Repeat-
edly push the piezo ignitor button until pilot is lit. Continue
to hold the control knob in for about one (1) minute after
the pilot is lit. Release knob and it will pop back up. Pilot
should remain lit. If it goes out, repeat steps 5 through
9.
• If knob does not pop up when released, stop and
immediately call your service technician or gas sup-
plier.
• If the pilot will not stay lit after several tries, turn
the gas control knob to "OFF" and call your service
technician or gas supplier.
10. Turn gas control knob counterclockwise
to
"ON".
11. Raise valve cover.
12. Turn on all electric power to the appliance (if appli-
cable).
13. Set thermostat to desired setting.
A. This appliance has a pilot which must be lighted by
hand. When lighting the pilot, follow these instructions
exactly.
B. BEFORE LIGHTING smell all around the appliance area
for gas. Be sure to smell next to the floor because some
gas is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch;
do not use any phone in your building.
• Immediately call your gas supplier from a neighbor's
phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire
department.
C. Use only your hand to push in or turn the gas control
knob. Never use tools. If the knob will not push in or turn
by hand, don't try to repair it; call a qualified service
technician. Force or attempted repair may result in a fire
or explosion.
D. Do not use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect
the appliance and to replace any part of the control system
and any gas control which has been under water.
1. Set the thermostat to lowest setting.
2. Turn off all electric power to appliance if service is to be
performed (if applicable).
3. Lower valve cover.
4. Push in gas control knob slightly and turn clockwise
to "OFF". Do not force.
5. Raise valve cover.
LIGHTING INSTRUCTIONS
FOR YOUR SAFETY READ BEFORE LIGHTING
LIGHTING INSTRUCTIONS
TO TURN OFF GAS TO APPLIANCE
WARNING: If you do not follow these instructions exactly, a fire or explosion may result
causing property damage, personal injury or loss of life.