background image

3-90-08327R26_03/14

Contact your local dealer with questions on installation, 

operation or service.

save these instructions.

installation & operating Manual

saFetY notice

Please read this entire Manual beFore You install and use Your new rooM heater. Failure to 

Follow instructions MaY result in ProPertY daMage, bodilY injurY, or even death.

For use in the u.s. and canada. the oakwood is not aPProved For Mobile hoMe installation.

iF this harMan® stove is not ProPerlY installed, a house Fire MaY result. For Your saFetY, Follow 

installation directions. 

contact local building or Fire oFFicials about restrictions and installation insPection 

reQuireMents in Your area.

contact Your local authoritY (such as MuniciPal building dePartMent, Fire dePartMent, Fire 

Prevention bureau, etc.) to deterMine the need For a PerMit.

cette guide d'utilisation est disPonible en Francais. chez votre concessionnaire de harMan® 

hoMe heating.

Model(s):

Oakwood Cast Iron Wood Stove

NOTICE: SAVE THESE INSTRUCTIONS

EPA Certified by 

OMNI-Test Laboratories

hot glass will cause burns.

•  Do not touch glass until it is cooled
•  NEVER allow children to touch glass
•  Keep children away
•  CAREFULLY SUPERVISE children in same room as 

stove.

•  Alert children and adults to hazards of high temperatures.

  high temperatures may ignite clothing or other 

flammable materials.

•  Keep clothing, furniture, draperies and other flammable 

materials away.

hot surFaces!

Glass and other surfaces are hot during 

operation and cool down.

WARNING

!

To  obtain  a  French  translation  of  this  manual,  please 

contact your dealer or visit www.harmanstoves.com

Pour obtenir une traduction française de ce manuel, s’il 

vous  plaît  contacter  votre  revendeur  ou  visitez  www.

harmanstoves.com

note

Wood Stove

Use & Care Video

Summary of Contents for Oakwood

Page 1: ...eau etc to determine the need for a permit Cette guide d utilisation est disponible en francais Chez votre concessionnaire de Harman home heating Model s Oakwood Cast Iron Wood Stove NOTICE SAVE THESE...

Page 2: ......

Page 3: ...eating appliance Failure to follow instructions may result in property damage bodily injury or even death Table of Contents 352 Mountain House Road Halifax PA 17032 U S A Contains updated information...

Page 4: ...ES LIBRES AUX COMBUSTIBLES A Du mur de c t l appareil 26 660mm B Du mur arri re l appareil 28 711mm C Du tuyau de chemin e au mur de c t 38 965mm D Du tuyau de chemin e au mur arri re 32 813mm E Entre...

Page 5: ...2 32 Grams Per Hour Emissions on Low 0 8 Grams Per Hour Log Length Recommended 21 Maximum BTU Hour Input 42 000 Heating Capacity 1 400 3 600 sq ft Outside Air Size 3 or 4 Inch Heating capacity to be u...

Page 6: ...wood 3 90 08327R26_03 14 SPECIFICATIONS Andirons Grate Top Load Opening Air Control Front Load Door Top Load Door Bypass Damper Control Handle Ash Door Ash Door Latch Front Load Door Latch Optional Co...

Page 7: ...fall into the ash pan by passing a poker back and forth across the grate The andirons keep the fuel from coming into direct contact with the glass and keep hot coals and embers from spilling out while...

Page 8: ...everal stages The initial or evaporation stage is where the moisture in the wood is driven off in the form of steam A second stage is where the volatile gases contained in the wood are released and bu...

Page 9: ...t finger width place several 1 2 25mm 50mm split pieces of dry wood on top of the kindling followed by a few 2 3 50 mm 80 mm split pieces Lay the wood in a crossed pattern to allow maximum air flow Ig...

Page 10: ...the bypass damper then the load door adding fuel and closing the door then the damper This depends on coal bed size load size and moisture content of fuel Removing Ashes Before reloading empty the ash...

Page 11: ...s other than those presented here INSTALLATION Parallel versus Corner Installations A parallel installation is one in which the back and sides of the stove are parallel to the walls behind and to the...

Page 12: ...12 Harman Oakwood 3 90 08327R26_03 14 INSTALLATION CLEARANCES See NFPA 211 for more installation clearance reductions when using USM wall protection etc 21 25...

Page 13: ...Harman Oakwood 13 3 90 08327R26_03 14 INSTALLATION CLEARANCES See NFPA 211 for more installation clearance reductions when using USM wall protection etc...

Page 14: ...14 Harman Oakwood 3 90 08327R26_03 14 installation clearances See NFPA 211 for more installation clearance reductions when using USM wall protection etc...

Page 15: ...es with hearth weight limitations The Oakwood should not be installed into a factory built fireplace unless the hearth area is designed to take the maximum weight of the stove The Oakwood loaded with...

Page 16: ...of space closet or other concealed space or through a floor or ceiling Whenever possible avoid passing the connector through a combustible wall if you must use an approved wall pass through described...

Page 17: ...e home installations a round flue either masonry or approved prefabricated of either 6 150 mm 7 180 mm or 8 200 mm may be used For square or rectangular masonry chimneys nominal sizes of 8 x 8 or 8 x...

Page 18: ...nry fireplace may be used to install your Oakwood In addition to the requirements found in the previous paragraphs it is important to be aware that all clearances must be met including those from the...

Page 19: ...urn up the air control lever setting and thoroughly ventilate your dwelling During future burns be careful not to overload the stove with fuel so you will not be tempted to constantly operate at a low...

Page 20: ...ilt Chimney Roof Flashing Chimney Cap Factory Built Metal Chimney Sealed Storm Collar Finishing Collar Chimney Connector Roof Radiation Shield Cathedral Style Chimney Support Chimney Cap Storm Collar...

Page 21: ...d air space Minimum of three sheet metal screws per joint of chimney connector Mantel and trim protection Airtight insulated clean out Damper closed and sealed with non combustible material Combustibl...

Page 22: ...ector Must Extend to Flue Liner Minimum 8 Masonry Thickness in Front of Smoke Chamber Use Damper Adapter or Seal with Non Combustible Material Floor Protection in Accordance with Solid Fuel Appliance...

Page 23: ...s Steel Flex Liner or Other Approved Lining System in Offsets Listed Fireplace Trim Protection for Reduced Clearance UL1777 Stainless Steel Liner System or Other approved lining system Follow liner ma...

Page 24: ...e liner with required air space Listed or approved thimble assembly 1 Clearance for exterior chimney or 2 clearance for interior chimney and 2 clearance for NFPA 211 type approved thimbles Airtight in...

Page 25: ...rfaces of the controls work the controls back and forth several times during the summer or any prolonged period when you are not using your stove The Fire Chamber The inside of the fire chamber should...

Page 26: ...ixed in place with a high temperature stove gasket cement To change a gasket first remove the worn fiberglass and clean the area with a wire brush Also clean any other surfaces that come into contact...

Page 27: ...installation the smoke deflector may not be needed on the top vent models The Cozy Screen can be used from the start of a fire or can be used with an existing one When starting a fire with the Cozy Sc...

Page 28: ...g Manufacturing date jan 2010 1 2 3 4 6 8 9 10 15 16 17 18 21 22 23 24 25 26 27 28 19 20 13 14 7 5 11 12 1 90 02490 1 black 1 90 02490 12 Forest green ending Manufacturing date jan 2010 1 90 02490 13...

Page 29: ...per Elbow Painted 3 50 00500S Y 7 Cook Grill Assembly Optional 1 00 08121 8 Flue Collar 4 00 249108D 9 Top Hinge Plate Qty 2 req 2 00 249147S 10 Top 4 00 249105P Gasket 30 Ft 1 00 00888 Y 11 Top Load...

Page 30: ...249188L 22 Ash Pan 1 10 249151 Y 23 Steel Ash Box Weldment 1 10 249144S 24 Ca Shield 2 00 249157B 25 Leg Qty 4 req 4 00 249100P Y 26 Bottom 4 00 249104D 27 Right Side Panel 4 00 249102D 28 Damper Fra...

Page 31: ...9117A Y 32 8 Grate 2 00 249122 Y 32 9 Cast Right Inside Plate w Gasket 1 10 249118A Y 32 10 Rear Brick Retainer Pkg of 2 1 00 249135 32 11 Shoe Brick 3 40 00100 Y Gasket shoe Brick 10 Ft 1 00 11862 Y...

Page 32: ...nty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent authorized HHT dealer distributor whichever occurs earlier The warranty...

Page 33: ...cover the following Changes in surface finishes as a result of normal use As a heating appliance some changes in color of interior and exterior surface finishes may occur This is not a flaw and is no...

Page 34: ...34 Harman Oakwood Date Of Service Performed By Description Of Service 3 90 08327R26_03 14 service maintenance log...

Page 35: ...35 Harman Oakwood 3 90 08327R26_03 14 NOTES...

Page 36: ...e This powerful heating appliance boasts uncompromising attention to detail and helps preserve our planet by using environmentally responsible fuels Signature of Boxer Your premium quality hearth prod...

Reviews: